2) Always insert the batteries into the compartment in the cor-
GB
rect way (see imprint in the compartment). When replacing
the fuse, only insert the type stated.
3) After replacing the batteries or the fuse, fasten the screws of
the battery compartment cover again before operating the
meter.
7 Specifications
DC and AC voltage
Measuring ranges: . . . . . . 200 mV, 2 V, 20 V, 200 V, 600 V
Measuring accuracy*
DC voltage: . . . . . . . . . ±(0.7 % + 2 digits)
200 mV~ to 200 V~: . . . ±(0.8 % + 3 digits)
600 V~:. . . . . . . . . . . . . ±(1.0 % + 3 digits)
Input resistance . . . . . . . . 10 MΩ
Overload protection
200 mV: . . . . . . . . . . . . 250 V / ~
2 V to 600 V: . . . . . . . . . 600 V / ~
Frequency range for AC: . 40 – 400 Hz
DC and AC current
Measuring ranges: . . . . . . 200 µA, 2000 µA, 20 mA, 200 mA, 2 A,
Measuring accuracy*
200 µA
2 A , 10 A : . . . . . . . ±(2.0 % + 10 digits)
200 µA~ to 200 mA~: . . ±(1.5 % + 5 digits)
2 A~, 10 A~: . . . . . . . . . ±(3.0 % + 10 digits)
Internal resistance
200 µA, 2000 µA: . . . . . 100 Ω
20 mA, 200 mA: . . . . . . 10 Ω
2 A, 10 A: . . . . . . . . . . . 1 Ω
Fuse protection
200 µA to 200 mA: . . . . fuse F200 mA / 250 V
2 A, 10 A: . . . . . . . . . . . not protected!
Frequency range for AC: . 40 – 400 Hz
Resistance
Measuring ranges: . . . . . . 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20 MΩ
Measuring accuracy*
200 Ω: . . . . . . . . . . . . . ±(1 % + 3 digits)
2 kΩ to 2 MΩ: . . . . . . . . ±(1 % + 1 digit)
20 MΩ: . . . . . . . . . . . . . ±(1 % + 5 digits)
22
10 A
to 200 mA : ±(1.2 % + 3 digits)