8 Specifications
GB
DC voltage/AC voltage
Measuring ranges: . . . . 400 mV, 4 V, 40 V,
Measuring accuracy*
400 mV : . . . . . . . . . . ± (0.5 % + 2 digits)
4 – 400 V : . . . . . . . . ± (1.2 % + 2 digits)
1000 V : . . . . . . . . . . ± (1.5 % + 2 digits)
400 mV~: . . . . . . . . . . ± (1.5 % + 70 digits)
4 V~: . . . . . . . . . . . . . ± (1.2 % + 3 digits)
40 V~ , 400 V~: . . . . . ± (1.5 % + 3 digits)
1000 V~: . . . . . . . . . . ± (2.0 % + 4 digits)
Input resistance: . . . . . . 7.8 MΩ
Overload protection: . . . 1000 V /~
Frequency range at V~: 50 – 400 Hz
Direct current/alternating current
Measuring ranges: . . . . 400 µA, 4 mA,
Measuring accuracy*
400 µA : . . . . . . . . . . ± (1.0 % + 3 digits)
4 – 400 mA : . . . . . . . ± (1.5 % + 3 digits)
10 A : . . . . . . . . . . . . ± (2.5 % + 5 digits)
400 mA~: . . . . . . . . . . ± (1.5 % + 5 digits)
4 – 400 mA ~: . . . . . . . ± (1.8 % + 5 digits)
10 A ~: . . . . . . . . . . . . ± (3.0 % + 7 digits)
Protection
µA and mA range: . . . F500 mAH/1000 V
10 A range: . . . . . . . . F10 AH/1000 V
Frequency range at A~: 50 – 400 Hz
Resistance
Measuring ranges: . . . . 400 Ω, 4 kΩ,
Measuring accuracy*
400 Ω: . . . . . . . . . . . . ± (1.2 % + 4 digits)
4 kΩ: . . . . . . . . . . . . . ± (1.0 % + 2 digits)
40 kΩ, 400 kΩ, 4 MΩ: ± (1.2 % + 2 digits)
40 MΩ: . . . . . . . . . . . . ± (2.0 % + 3 digits)
Overload protection: . . . 600 V /~
18
400 V, 1000 V
40 mA, 400 mA, 10 A
40 kΩ, 400 kΩ,
4 MΩ, 40 MΩ
Capacitance
Measuring ranges: . . . . 4 nF, 40 nF, 400 nF,
Measuring accuracy*
4 nF: . . . . . . . . . . . . . ± (5.0 % + 20 digits)
40 nF: . . . . . . . . . . . . ± (5.0 % + 7 digits)
400 nF, 4 µF, 40 µF: . . ± (3.0 % + 5 digits)
200 µF: . . . . . . . . . . . ± (5.0 % + 5 digits)
Overload protection: . . . 600 V /~
Frequency
Values only for position Hz% of selector switch
Measuring ranges: . . . . 9,999 Hz, 9,999 kHz
Measuring accuracy*
9.999 Hz, 99.99 Hz: . . ± (1.5 % + 5 digits)
999.9 Hz – 999.9 kHz: ± (1.2 % + 3 digits)
9.999 MHz: . . . . . . . . ± (1.5 % + 4 digits)
Sensitivity
at ≤ 1 MHz: . . . . . . . . 0.5 V~
at > 1 MHz: . . . . . . . . 3 V~
Overload protection: . . . 600 V /~
Duty cycle
Values only for position Hz% of selector switch
Measuring range: . . . . . 0.1 – 99.9 %
Measuring accuracy* . . ± (1.2 % + 2 digits)
Sensitivity: . . . . . . . . . . . 0.5 V~
Frequency range: . . . . . 5 Hz – 150 kHz
Overload protection: . . . 600 V /~
Diode test
Indication: . . . . . . . . . . . forward voltage
Measuring accuracy*: . . ± (10 % + 5 digits)
Measuring current: . . . . approx. 0.3 mA
Max. measuring voltage: approx. 1.5 V
Overload protection: . . . 600 V /~
* at 23 °C, ±5 % relative humidity < 70 %
4 µF, 40 µF, 200 µF
99,99 Hz, 99,99 kHz
999,9 Hz, 999,9 kHz
9,999 MHz
up to 0.999 V