rated voltage and current of the BENNING MM 7-1.
-
Check the insulation of the safety measuring leads. If the insulation is dam-
aged in any way, do not use the leads.
-
Check the continuity of the safety measuring leads. If the conductor in the
safety measuring lead is interrupted, do not use the leads.
-
Before selecting another function with the rotating switch , always discon-
nect the safety measuring leads from the measuring point.
-
Sources of strong current in the vicinity of the BENNING MM 7-1 may
cause unstable or incorrect readings.
8.2 Voltage and current measurement
Always observe the maximum voltage to earth potential!
Electrical hazard!
The maximum voltage which may be applied to the sockets
-
COM- socket
-
socket for V, Ω, Hz, ,
-
socket for mA range and the
-
socket for 10 A range
of the BENNING MM 7-1 to earth is 600 V CAT IV/ 1000 V CAT III.
8.2.1
Voltage measurement
-
With the rotating switch , select the desired function ( ,
LoZ) on the BENNING MM 7-1.
-
Select the voltage type to be measured (direct voltage DC, alternating volt-
age AC or AC+DC) by means of the blue key of the BENNING MM 7-1.
-
Connect the black safety measuring lead to the COM socket on the
BENNING MM 7-1.
-
Connect the red safety measuring lead to the socket for V, Ω, Hz, ,
on the BENNING MM 7-1.
-
Connect the safety measuring leads to the measuring points. Read the meas-
urement value displayed in the digital display of the BENNING MM 7-1.
See fig. 2:
See fig. 3:
Note:
On the digital display , the "AutoV/ LoZ" function is displayed by the "Auto
Sense/ Lo-Z" symbol. It automatically determines the required measuring func-
tion (AC/ DC voltage) and the ideal measuring range. Moreover, the input resist-
ance is reduced to approx. 3 kΩ in order to suppress inductive and capacitive
voltages (reactive voltages).
8.2.2
Current measurement
-
With the rotating switch , select the desired range and function (mA or A)
on the BENNING MM 7-1.
-
Select the current type to be measured (direct current DC, alternating cur-
rent AC or AC+DC) by means of the blue key of the BENNING MM 7-1.
-
Connect the black safety measuring lead to the COM socket on the
BENNING MM 7-1.
-
Connect the red safety measuring lead to the socket for mA range, for
current up to 600 mA or to the socket for the 10 A range, for currents
greater than 600 mA up to 10 A on the BENNING MM 7-1.
-
Connect the safety measuring leads to the measuring points. Read the meas-
urement value displayed in the digital display of the BENNING MM 7-1.
See fig. 4:
See fig. 5:
8.3 Resistance measurement
-
With the rotating switch , select the desired function (Ω,
BENNING MM 7-1.
-
Connect the black safety measuring lead to the COM socket on the
BENNING MM 7-1.
-
Connect the red safety measuring lead to the socket for V, Ω, Hz, ,
on the BENNING MM 7-1.
-
Connect the safety measuring leads to the measuring points. Read the meas-
urement value displayed in the digital display of the BENNING MM 7-1.
See fig. 6:
8.4 Diode testing
-
With the rotating switch , select the desired function ( ,
BENNING MM 7-1.
-
Using the blue key on the BENNING MM 7-1, switch to diode testing.
07/ 2016
DC-voltage measurement
AC-voltage measurement
DC-current measurement
AC-current measurement
Resistance measurement
BENNING MM 7-1
,
, AutoV/
) on the
) on the
21