How To Operate the Machine

How to Operate the Squeegee and the Vacuum Motor

The squeegee wipes the fl oor while the vacuum motor removes the dirty
solution from the fl oor. To operate the squeegee, follow this procedure:
1.
To lower the squeegee and start the vacuum motor, press the
squeegee up/down switch to the down position (fi gure 24).
NOTE: The vacuum motor will start immediately when the
down position of the switch is pressed, and the squeegee
will lower.
2.
To raise the squeegee, press the squeegee up/down switch to
the up position (fi gure 24). The squeegee will then raise and the
vacuum motor will shut off after short delay NOTE: The center
position of the squeegee up/down switch is for use with one
touch control.
NOTE: The squeegee will raise automatically when traversing in
reverse during scrubbing operations.

How to Operate the Solution Flow

The solution is used to loosen and remove dirt from the fl oor. The amount
of solution applied can be adjusted to fi ve different levels to accommo-
date many different fl oor conditions. These different levels are shown
on the LCD display on the front of the machine. To adjust the amount of
solution applied, use the Solution Flow Switch (fi gure 25). NOTE: There
are fi ve different settings on the display. See fi gure 26, A.
To increase solution fl ow:
1. Press the " + " side of the switch (fi gure 25).
2. Press and hold the " + " switch to achieve the desired level of solu-
tion fl ow.
To decrease solution fl ow:
1. Press the " - "
side of the switch (fi gure 25).
2. Press and hold the " - " side of the switch to achieve the desired
level of solution fl ow.
How to Operate the Brush Pressure
The brushes are used to supply agitation for the solution, which improves
the cleaning process. The amount of brush pressure applied can be
adjusted to fi ve different levels to accommodate many different fl oor con-
ditions. These different levels are shown on the LCD display on the front
of the machine (fi gure 26, B). To adjust the amount of brush pressure,
use the brush up/down switch (fi gure 27).
To increase brush pressure:
1. Press the " + " side of the switch (fi gure 27).
2. Press and hold the " + " switch to achieve maximum level of pres-
sure.
To decrease brush pressure:
1. Press the " - "
side of the switch (fi gure 27).
2. Press and hold the " - " side of the switch to achieve minimum or no
brush pressure.