Decommissioning And Disposal; Technical Data - ProMinent CONCEPTPLUS Instrucciones De Servicio

Ocultar thumbs Ver también para CONCEPTPLUS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Decommissioning and disposal / Technical data
10
IMPORTANT
• When decommissioning a pump, clean all traces of chemicals
• Observe all relevant disposal directives for your area
11
Performance table 230 V version
Pump
Minimum delivery rate
type
at maximum
back pressure
bar
l/h
1000
10
0.6
1601
16
1.0
1002
10
2.0
0704
7
3.9
0308
3
8.0
0213
1.5
13.5
* Suction lift with filled suction line and liquid end
** Priming lifts with clean and wetted valves, metering fluid, water
Materials
Liquid end material specification: see type code
Housing:
Electrical data
Mains frequency:
* Fuses must have approvals according to VDE, UL and CSA.
22

Decommissioning and disposal

and dirt from the housing and particularly the liquid end.
(particularly with regard to electronic waste)

Technical data

Minimum feed rate
at medium
back pressure
ml/
stroke
bar
l/h
0.07
5
0.8
0.10
8
1.4
0.18
5
2.6
0.39
3.5
4.5
0.74
1.5
10.8
1.42
1.0
15.5
(20 °C), at 100 % stroke length, 180 strokes/min, atmospheric
pressure outlet and/or open venting valve and correctly installed lines.
230 V/AC version
Wattage:
Current I eff:
Peak current
Switch-on peak current
< 4 A for < 0.1 ms
Fuse*:
Max.
Connection
stroke
size
rate
ext. Ø x int. Ø
ml/
strokes/
stroke
min
mm
180
0,08
6x4
180
0.13
6x4
0.24
180
6x4
0.42
180
6x4
1.00
180
8x5
1.4
180
8x5
PPE, glass fibre reinforced
50 Hz / 60 Hz
CNPa
10 W
0.12 A
0.5 A
0.16 AT
Priming
Priming
lift
*
lift
**
m Wc
m Wc
6
1.8
6
2.0
5
2.5
4
3.0
2
2.0
1.5
1.5
115 V/AC version
Wattage:
Current I eff:
Peak current
Switch-on peak current
< 3 A for < 0.1 ms
Fuse*:
Admissible
priming pressure
Intake
bar
8
8
5.5
3
1
0.5
CNPa
11 W
0.26 A
1.2 A
0.315 AT
ProMinent
®

Publicidad

Tabla de contenido
loading