1) GENERAL OUTLINE

The DEIMOS BT actuator offers ample installation versatility thanks to its
compactness, the extremely low position of its pinion as well as the height
and depth adjustments available. The adjustable electronic torque limiter
ensures antisquash safety. The emergency manual manoeuvre can be
activated very easily by means of a knob. The end-of-run stop is controlled
by electromechanical limit microswitches. The control unit is incorporated.
The following optional accessories are available:
- SBBAT mod. Buffer battery kit
It can be incorporated into the actuator, and allows the automation system to
operate even when the mains power supply is disconnected for a short time.
- MSC mod. Release knob (fig.2)
Fixed release knob with personalised key.
2) SAFETY
If correctly installed and used, this automation device satisfies the required
safety level standards. However, it is advisable to observe some practical
rules in order to avoid accidental problems.
Before using the automation device, carefully read the operation instructions
and keep them for future reference.
Keep children, persons and things outside the automation working area,
particularly during operation.
Keep radio control or other control devices out of children's reach, in
order to avoid any unintentional automation activation.
Do not intentionally oppose the leaf movement.
Do not attempt to open the gate by hand, if the actuator has not been
released by means of the appropriate release knob.
Do not modify the automation components.
In case of malfunction, disconnect the power supply, activate the
emergency release to gain access to the actuator and request the
assistance of a qualified technician (installer).
Before proceeding to any external cleaning operation, disconnect the
mains powers supply and at least one of the battery pole, if fitted.
Keep the photocell optical components and luminous signal indication
devices clean. Check that the safety devices (photocells) are not obscured
by branches or shrubs.
For any direct assistance to the automation system, request the
assistance of a qualified technician (installer).
Have qualified personnel check the automation system once a year.

3) MANUAL RELEASE

The manual or emergency release is to be activated when a gate must be
opened by hand, and in all cases where the automation system fails to
operate or operates incorrectly. To carry out the emergency manoeuvre,
proceed as follows:
Insert the standard key into its appropriate seat (fig. 1) and rotate it
anticlockwise (90°), then rotate the release knob clockwise along its
entire stroke. This way the pinion is made to idle, and therefore allows
the gate to be opened by hand.
Warning: Do not push the gate leaf hard, but rather help it along its
entire stroke.
To reset motor-driven control, rotate the knob anticlockwise along its
entire stroke, and then rotate the standard key clockwise until it is held
tight. Keep the key in a safe place which is known to all the people
concerned.
In the case where the release knob is supplied with a personalised key
(fig.2), proceed as follows:
Insert the personalised key into the lock, rotate the key anticlockwise by
90°.
Hold the release knob and rotate it clockwise (fig. 2) until it stops. This
way the pinion is made to idle, and therefore allows the gate to be
opened by hand.
Push the gate leaf by hand, helping it along its entire stroke.
The key cannot be taken out of the lock until the knob is brought back
to its initial position (motor-driven activation).
To reset motor-driven control, rotate the knob anticlockwise along its
entire stroke, move the key back to its locking position; then take the key
out and keep it in a safe place which is known to all the people concerned.
4 -
DEIMOS BT Ver. 04
USER'S MANUAL
4) MAINTENANCE AND DEMOLITION
The maintenance of the system should only be carried out by qualified
personnel regularly. The materials making up the set and its packing must
be disposed of according to the regulations in force.
WARNINGS
Correct controller operation is only ensured when the data contained
in the present manual are observed. The company is not to be held
responsible for any damage resulting from failure to observe the
installation standards and the instructions contained in the present
manual.
The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product
features unchanged, at any time and without undertaking to update
the present publication.
http://www.bakonline.net/
Fig. 1
1
2
Fig. 2
MSC
1
2

Publicidad

Tabla de contenido
loading

Tabla de contenido