3. Specifications / 4. Design and function
3. Specifications
Specifications
GB
Measuring range
Measuring deviation
per DIN IEC 770,
Nominal size
Material
Ingress protection
Electromagnetic compatibility (EMC) CE-Conformity per DIN EN 61326-2 (1998-01)
Sensor
Vibration (at sensor)
Shock (at sensor)
Weight
1) In defined measuring range
For further specifications see WIKA Data Sheet TE 60.75 and the order documentation.
4. Design and function
4.1 Description
The DiwiTherm
thermometer. This compact thermometer can be used in a wide range of applications and
works without an external power supply.
A wide variety of possibilities for the combination of insertion length, neck length, connection
to thermowell etc. are available for the thermometers, suitable for any thermowell and any
application.
Operation without a thermowell is only appropriate in special cases.
Optionally, the DiwiTherm
measuring the temperature on a pipe's surface.
4.2 Scope of delivery
Cross-check scope of delivery with delivery note.
8
1)
23 °C ± 5 K
Model TR75 is the ideal combination of a digital display and a resistance
®
Model TR75 can be manufactured with a process connection for
®
Model TR75
-50 ... +199,9 °C or -50 ... +450 °C
≤ 1 % of upper limit of range
100
Stainless steel
IP 65 per EN 60529 / IEC 529
Pt1000
10 ... 500 Hz 5 g DIN EN 60068-2-6
50 g DIN EN 60068-2-27
approx. 1 kg
WIKA operating instructions DiwiTherm
, model TR75
®