2. Safety / 3. Specifications
GB
3. Specifications
Temperature ranges
Medium temperature (measuring range)
The measuring range mainly depends on the measuring element:
Measuring element
NTC
Pt100
Pt1000
Ni1000
KTY
Ambient temperature
The permissible ambient temperature depends on the electrical connection:
Electrical connection
Plug connector type AMP Junior Power
Timer
FASTON blade terminals
Connector Deutsch DT04-2P
Bayonet connector DIN 72 585
Circular connector M12 x 1
Storage temperature
-40 ... +85 °C
Protect the measuring instrument from humidity and dust!
8
WIKA Operating Instructions Screw-in Thermometers, Model TF35
Do not use this screw-in thermometer in safety or Emergency
Stop devices. Incorrect use of the screw-in thermometer can
result in injury.
Should a failure occur, aggressive media with extremely high
temperature and under high pressure or vacuum may be present
at the screw-in thermometer.
Measuring range
-40 ... +130 °C
-50 ... +200 °C / -50 ... +300 °C
-50 ... +200 °C / -50 ... +300 °C
-50 ... +200 °C
-50 ... +150 °C
Due to its short immersion length there is a possibility that the
temperature at the plug will rise to an inadmissibly high level.
This must be considered in the design of the measuring point.
Ambient temperature
-40 ... +150 °C
-40 ... +150 °C
-40 ... +150 °C
-40 ... +140 °C
-40 ... +100 °C