User and Service Manual
Digital Control for HELO HSX Steam generator
WARNING
Installation and mending must be performed by qualified personnel in the respect of all the following safety norms:
DLGS N°615/96 del 12/11/96 (ECC Document 89/336 on Electromagnetic compatibility)
DLGS N°626/96 del 26/11/96 (ECC Document 93/68 on Low Voltage)
The present manual is addressed to technical personnel qualified for installation
The "HSX DIGITAL CONTROL PANEL" System is an electronic device that controls the following functions:
x
Steam Bath On/Off
x
Adjustable bathing time and temperature
x
Light
x
Fan
x
Essence Pump
x
4 programmable/preset programs
x
Alarm analyses
Power inlets
x
1 serial inlet for the keyboard
x
2 resistive level sensors (predisposed for capacitive or ultrasound level sensors)
x
Supply 5VCC, digital exit: open collector NPN
x
The high level sensor has to have adjustable sensitivity
x
2 dip switch
x
1 normally closed connector for a remote timer
Outputs
x
1 serial output for controlling the next control (without using a split box)
x
1 lamp 12VAC – 35 WATTS MAX.
x
1 water-charging electro valve 230 VAC
x
1 drain electro valve 230 VAC
x
1 essence pump A 230VAC MAX 400WATTS.
x
1 fan 230VAC MAX 400WATTS.
x
1 steam generator output (remote control switch coil) 230VAC MAX 3000W
Details
Board dimension: 10CMX11 CM
Second transformator to supply level sensors
PRODUCT DESCRIPTION
DESCRIPTION OF CONNECTIONS
13