Astralpool HELO HSX Manual De Uso página 44

El generador de vapor
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Mounting the Split kit:
1. Remove the short plastic-end cover
and the metallic top cover from the
HSX steam-generator.
2. Open the 19mm diameter pre-
drilled hole on the inside of the
shorter plastic-end cover of the
HSX-steam generators.
3. Mount the Split-kit cable and strain
relief to the opened hole in the
plastic end cover
4. Connect the wire/wires from the
Split-kit to the PC-board connector
according to the drawing and set the
DIP-switch 1 and 2, in the
following positions according to the
steam generators connection
number:
HSX 1:
HSX 2:
HSX 3:
HSX 4:
5. Set the adjustable drain cycle, dip 3
and 4, on the PC-board on each
HSX steam generator
No drain cycle
3 hour
3hour 20min.
3hour 40min.
DIP1 DIP2
off
off
on
off
off
on
on
on
DIP3 DIP4
off
off
off
on
on
off
on
on
1
1.
2./ 3.
4.
pre-drilled
holes.
21mm
21mm
19mm/Split-Kit
22