Temperature and Time setting
The temperature set by default is 45°C and it can be changed from 30°C to 50°C with steps of 1°C by using the
plus and minus key. The temperature can be changed also after the set steam bath program has started, by
pressing the temperature key and subsequently the plus and minus keys within 2 seconds.
Time can be changed by using the time key and the plus and minus keys.
The Steam generator
When the user starts the treatment the electro valve starts taking in water, when the water reaches the low level
sensor the heating starts.
When the water reaches the high level sensor the electro valve closes off; as soon as the high level sensor does not
feel the water the electro valve opens and it closes when the right level is reached.
Steam generator cleaning cycle
The cleaning cycle is an automatic operation and is very important because it prevents the formation of chalk and
bacteria in the water tank.
It is automatically activated 15 minutes after the steam generator has stopped. The drain electro valve opens for 2
minutes. The tank is filled with water up the high level sensor, and the draining electro valve opens again for two
minutes.
During the cleaning cycle the external segments of the display go around in circles.
The led is on when the lamp is off. Press the lamp key and the led switches off while the lamplight is on.
The lamp works independently from the steam generator .
The fan switches on automatically when the generator stops, and then the fan runs for 30 min.
During the steam bathing the fan can be switched on and off.
The led shows the status of the fan: on when the fan works and off when the fan is off.
The essence pump starts working automatically when the set temperature is reached. It can stopped and restarted
by pressing the essence pump key. The led is on when the pump is on and off when the pump is off.
There are 4 memory keys with default steam bath programs.
In order to memorize a personal steam bath, adjust temperature and time by using the plus and minus keys and
then press a memory key for more than 2 seconds: in this way the customized steam bath program is saved in the
memory key. The Memory keys all work as starting keys for the steam bath program
The led of the memory key is on when the chosen steam bath program is on. When the user is programming a key
the led blinks, while saving the new data, in order to show that the reprogramming operation has been successfully
performed.
If a problem occurs in the system while in function, the display visualizes an alarm number (A1, A2, A3, A4), which
helps identify the nature of the problem.
x
A1: If the high level sensor does not feel the water after 5 minutes from activating the steam bath, the
system times out and it can be re-started. If the system does not get restarted after 5 minutes then the
draining valve empties the water tank.
x
A2: If the low level sensor does not feel the water for more than 1 minute during the treatment, the
heating stops working. If the operator doesn't make any operational actions within 5 minutes then the
whole system times out.
x
A3: If the set temperature is not yet reached after 30 minutes the display visualizes the alarm. The steam
bath continues according to program. Check the set temperature, sensor position, ventilation and
dimensioning of the generator if the A3 shows again.
x
A4: If the temperature level does not work all functions are inhibited
STEAM BATH FUNCTION
LAMP
ESSENCE PUMP
PRE PROGRAMMABLE BUTTONS
FAN
ALARMS
..
17