Installation
(Continued)
2. If repair or replacement of cord or
plug is necessary, do not connect
grounding wire to either flat blade
terminal. The wire with insulation
having an outlet surface that is green
with or without yellow stripes is the
grounding wire.
3. Check with a qualified electrician or
serviceman if grounding instructions
are not completely understood, or if in
doubt as to whether product is
properly grounded. Do not modify
plug provided; if it will not fit outlet,
have proper outlet installed by a
qualified electrician.
Never connect
WARNING
!
green (or green and
yellow) wire to a live terminal.
Operation
FOR TROUBLE-FREE OPERATION
1. Read instructions: Carefully read
through this owner's manual BEFORE
OPERATING the new air compressor.
It contains information about
operation and maintenance of unit.
Do not attach air
CAUTION
!
chuck or other tool
to open end of hose until start-up has
been completed and unit checks OK.
2. Turn regulator knob fully clockwise.
Close
Figure 2
3. Turn switch to OFF position, and plug
in power cord.
4. Turn switch to ON position.
Off
position
Figure 3
Length of Cord (ft)
Gauge of Cord
Wire
Power cord
Motor cord
Power cord
Motor cord
( ) When the unit is not in operation
5. Turn regulator knob fully
counterclockwise. Compressor will
build to maximum preset pressure and
shut off.
6. Turn regulator knob clockwise to
cause air to bleed off. Compressor will
restart at present pressure.
7. Turn regulator knob counterclockwise
to shut off air and turn switch to OFF
position.
8. Attach air chuck or other tool to open
end of hose. Turn regulator fully ON.
Apply a soap and water solution
around hose fittings and check for
signs of leaks (bubbles forming). If
there is a leak, tighten connections
and check again. When there are no
leaks, compressor is ready for
operation.
Figure 4
Open
9. Drain tank daily: Open drain cock and
drain moisture from tank. Be sure to
close cock tightly before operating
compressor. This helps prevent tank
corrosion and keeps oil and moisture
out of air used.
ASME SAFETY VALVE
1. This valve automatically releases air if
air receiver pressure exceeds preset
maximum.
On
DANGER
!
position
valve!
2. This valve should be checked
occasionally by pulling the ring by
Extension cords for 120V/5 Amp Unit
25
50
100
18
18
14
Wire and Terminal Guide
Color
White
White
Black
Black
REGULATOR KNOB
1. This knob controls air pressure to an air
Do not attempt to
2. Turning knob clockwise increases air
tamper with this
3. Turning counterclockwise will lower air
150
200
250
12
12
10
3
Terminal
Line
Load
Line
Load
MOISTURE IN COMPRESSED AIR
Moisture in compressed air will
form into droplets as it comes
from an air compressor pump.
When humidity is high or when a
compressor is in continuous use
for an extended period of time,
this moisture will collect in the
tank. When using a paint spray or
sandblast gun, this water will be
carried from the tank through the
hose, and out of the gun as
droplets mixed with the spray
material.
IMPORTANT: This condensation
will cause water spots in a paint
job, especially when spraying
other than water based paints. If
sandblasting, it will cause the
sand to cake and clog the gun,
rendering it ineffective.
A filter in the air line, located as
near to the gun as possible, will
help eliminate this moisture.
hand. If air leaks after ring has been
released, or valve is stuck and cannot be
actuated by ring, it MUST be replaced.
Figure 5
operated tool, or paint spray gun.
pressure at outlet.
pressure at outlet.
300
400
10
8
FP2021
Hot
No
No
Yes
Yes
500
8