Emptying The Used Oil Container; Replacing The Printer Paper; Unscheduled Maintenance / Calibration; Calibrating The Bottle Scale - Launch VALUE-200 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 123
Refer to collapsible tracer cartridge precautions [MANU008.ATS].

EMPTYING THE USED OIL CONTAINER

This operation must be performed whenever the oil level exceeds 200 cc. Procedure: remove
the container from its lodging very carefully and without exerting pressure on the scale.
Unscrew the container while holding the cap in place; empty the used oil into a suitable
container for used oils. Screw the container back on while holding the cap in place. Carefully
replace the container in its lodging without exerting pressure on the scale. N.B.: In order to
avoid damage to the oil scale, never exert pressure on it either from above or from below.

REPLACING THE PRINTER PAPER

Use only heat-sensitive paper of the type described below.
Paper width: 58 mm
Maximum paper roll diameter: 40mm

UNSCHEDULED MAINTENANCE / CALIBRATION

Perform this operation whenever the values displayed on the LCD do not correspond to real
values. WARNING: The operations listed below must be performed with maximum attention
and care. In particular, always observe the following precautions. Always place the weights at
the center of the scale plate. Never exert pressure on the oil scale. Always recover the gas in
the high- and low-pressure hoses before beginning calibration of the transducers.
To enter the CALIBRATION MENU:
Switch the machine on. The MAIN MENU will appear after a few seconds:
Select NEXT MENU:
Now select CALIBRATION from the menu:
Type the code 0791 and press ENTER to confirm.

CALIBRATING THE BOTTLE SCALE

Disconnect the machine from the electrical supply. Procure a known reference weight from 16
to 18 kg. Remove the plastic cover on the rear of the machine to access the machine bottle.
Close the blue and red taps on the bottle. Unscrew the bottle lock nut (3 – Fig. 4). Separate the
heating coil (r – Fig. 8) from the bottle (do not touch or disconnect the wires of the resistance
coil). Remove the bottle (d – Fig. 8) from its lodging, leaving the resistance around the scale
plate. Set the bottle on a stand at least 40 cm in height.
Access the CALIBRATION MENU as explained above.
The following will be displayed:
INSTRUCTIONS MANUAL
AUTOMATIC PROCEDURE
ASSISTED PROCEDURE
NEXT MENU
Gas Avail
xxxxx G
<CALIBRATION>
DATA AND CONFIGURAT.
SERVICE ALARM
BOTTLE FILLING
To enter calibration
insert code
....
And press ENTER
-20-

Publicidad

Tabla de contenido
loading

Productos relacionados para Launch VALUE-200

Tabla de contenido