Autosalt Model®
CHLORINATOR CONTROLLER BOX (distance from the cell = 2m maximum)
1
1/ Choose a location that is easily accessible, close to the pump contactor. Install the controller box
vertically, far enough away from the pool to comply with the regulatory distance in force in your country. Do
not cover.
2/ Connect the chlorinator controller box to the electrical distribution box permanently, controlled by the
pump contactor. Do not use an extension cord. Do not plug the device into an electric power outlet.
Beforehand, turn off the differential circuit breaker. Ensure that the controller box well switches off when
the filtration pump stops.
CHLORINATOR CELL (length = 22,5 cm)
2
1/ Install the cell horizontally and after every other water treatment device or cleaning or heating device
(and as close as possible to the return jets).
2/ Install successively the water tightness seals, and then the collars and tighten the nuts by hand. Stick the
group on the pipe.
3/ Use, if necessary, the 63/50 PVC pipe reducers supplied.
4/ Connect the cable to the cell and to the device.
5/ The 2 terminals (Brown and Blue) can be mounted either way on one of the borders of cell.
6/ Install the lock washers and the nuts, and then tighten nuts (using a size 10 spanner), gently, until the
blocking.
AUTOSALT®/POOLSQUAD®/POOLSQUAD® AMPERO/PRO - PAPI004082 – FR/EN/ES/DE - Rev.03.16
Flow sensor in option
5