POOL Autosalt Manual De Usario página 49

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CAREFUL
Cell power
OK
CAREFUL
Low pH
OK
CAREFUL
TOO HIGH PH
OK
SECURITY
PH REGULATION
OK
SECURITY
NO FLOW
OK
SECURITY
DEFECT OF CHLORINE
OK
GEL CL probe
OK
AUTOSALT®/POOLSQUAD®/POOLSQUAD® AMPERO/PRO - PAPI004082 – FR/EN/ES/DE - Rev.03.16
Chlorination ON
pH Regulation ON
Chlorination
ON
Acid
pH
mode
Regulation
STOP
Chlorination
ON
Basic
pH
mode
Regulation
STOP
Chlorination
ON
Acid
pH
mode
Regulation
STOP
Chlorination
ON
Basic
pH
mode
Regulation
STOP
Chlorination ON
pH Regulation STOP
Chlorination STOP
pH Regulation OFF
Chlorination STOP
pH Regulation ON
Chlorination ON
pH Regulation ON
Detection of a defect of chlorine production.
Make a chlorination test (see § 7) to determine the origin of the
defect.
You have to measure pH level with usual analysis kit. If this one
corresponds to POOLSQUAD display, you have to wait until pH goes
back up. If it doesn't match, you have to check proper functioning of
pH probe with a new manual calibration.
1/ Check that corrective tin solution is not empty
2/ Check that the probe injects correctly by making a manual
injection particular menu.
3/ Check the smooth running of the pH probe in doing again a manual
calibration.
4/ Check the injection and pursuit valves.
1/ Check that corrective tin solution is not empty
2/ Check that the probe injects correctly by making a manual
injection particular menu.
3/ Check the smooth running of the pH probe in doing again a manual
calibration.
4/ Check the injection and pursuit valves.
You have to measure pH level with usual analysis kit. If this one
corresponds to POOLSQUAD display, you have to wait until pH goes
back up. If it doesn't match, you have to check proper functioning of
pH probe with a new manual calibration.
Regulation problems (the last pH corrective attempts are
unsuccessful). All models excepted Autosalt®
1/ Check that the corrective tin is not empty.
2/ Check that the probe injects correctly by making a manual
injection in the pH setting menu.
3/ Check the smooth running of the pH probe in doing again a manual
calibration (see § 6.2).
4/ Check the injection and pursuit valves.
If flow sensor in option is installed.
Detection of a lack of flow in waterworks.
Make sure the presence of water in piping (check the opening of
valves) and filtering pump working.
Only for Poolsquad® Ampéro
Detection of a defect in the automatic probe regulation.
It could have many causes :
1/ Check the flow in the measure chamber.
2/ Check the presence of gel in the probe. If necessary, add gel (see §
6.5).
3/ Chlorine probe out of order: change in the chlorine probe.
4/ Chlorine probe bad connected or not linked: check that the probe
is correctly linked.
Only for Poolsquad® Ampéro model
Alarm triggered
The last change of gel goes back of 60 days (by default) : you have to
change the gel.
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

PoolsquadPoolsquad amperoPoolsquad pro

Tabla de contenido