Problem
"MCP ERR" appears on
the display. (MCP-6A
communications error)
Concerning the received frequency display, an unmodulated signal may be
received. This is according to the set intrinsic frequency form.
(144 MHz + 45.05 MHz) x 2 – (430 MHz - 49.95 MHz)
VxU reception
(144 MHz + 45.05 MHz) x 4 – (430 MHz - 49.95 MHz) x 2 = 45.05 MHz, 49.95 MHz
(430 MHz - 45.05 MHz)
UxV reception
(430 MHz - 45.05 MHz) x 2
44
Probable Cause
1 There is a problem
with the connection
between the
TM-D710G and the
PC.
2 The PC is performing
a large amount of
processing.
3 EchoLink mode is
ON.
4 There are other
reasons why
communications was
not possible.
<A band>
– (144 MHz + 49.95 MHz) x 2 = 45.05 MHz, 49.95 MHz
– (144 MHz + 49.95 MHz) x 4 = 45.05 MHz, 49.95 MHz
Corrective Action
1 Ensure that the connection
between the TM-D710G
and the PC is correct.
2 Shut down other software
that you may be running.
3 Turn EchoLink mode OFF.
4 Turn the TM-D710G power
source OFF and then back
ON.
<B band>
= 45.05 MHz, 49.95 MHz