Making Air Inlet And Outlet Vents - Dometic 10 Serie Instrucciones De Montaje

Nevera con extractor
Ocultar thumbs Ver también para 10 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
RM10.5(S)(T), RMS10.5(X)(S)(T)
➤ Push the refrigerator-oven combination against the double lipped sealing on fur-
niture.
✓ The space behind the refrigerator is sealed to the interior of the vehicle.
4.3

Making air inlet and outlet vents

I
NOTE
• Deviations from the inlet and outlet variations shown here must be
approved by the manufacturer.
• At high ambient temperatures, the refrigerator can only provide its
maximum cooling capacity if the optimum ventilation has been pro-
vided.
➤ Make an air inlet vent and an air outlet vent in the outer wall with the size of
451 mm x156 mm.
When doing so, observe the information, see chapter "Preparing the installa-
tion" on page 18.
If the ventilation grill of the air inlet vent cannot be installed flush with the floor of the
niche, install an inlet vent in the floor. Any leaking gas can thus flow downwards.
➤ Make an air inlet vent of at least Ø 40 mm in the floor (fig. 9 1, page 8) behind
the refrigerator near the gas burner.
➤ Shield the outside of the opening with a deflector to prevent sludge or dirt from
getting inside while driving (fig. 9 2, page 8).
If you have to use a roof vent instead of the air outlet vent:
➤ Cut out a section in the roof. Refer to the roof vent instruction manual for the
required dimensions.
When doing so, observe the information in chapter "Preparing the installation"
on page 18.
EN
Installing the refrigerator
21

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rm 10.5sRm 10.5tRms 10.5xRms 10.5sRms 10.5t

Tabla de contenido