Decommissioning; Decommissioning Procedure; Disposal; Disposal/Recycling - Baxi EVOlution PRIME 28 Manual De Uso

Ocultar thumbs Ver también para EVOlution PRIME 28:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30

10. DECOMMISSIONING

10.1 Decommissioning procedure

Before disassembling the device, check that it is has been disconnected from the mains and that the gas tap upstream of the
boiler has been shut.
11.

DISPOSAL

11.1 Disposal/Recycling

Only qualified technicians are authorised to service the device and system.
Before dismantling the appliance, be sure to disconnect the power supply, close the gas inlet shutoff valve and secure all of the
boiler and system connections.
Dispose of the appliance correctly according to the laws and regulations in place. The appliance and accessories cannot be
discarded along with normal household waste.
More than 90% of the materials that make up the appliance are recyclable.

12. ENVIRONMENT

12.1 Energy saving

Adjusting the CH
Adjust the boiler flow temperature depending on the kind of system. For systems with radiators, set a maximum heating water flow
temperature of approximately 60°C, and increase this value if the required room temperature is not reached. For systems with
radiant floor panels, do not exceed the temperature indicated by the system designer. Use the External Sensor and/or Room Unit
to automatically adjust the flow temperature to atmospheric conditions or the indoor temperature. This ensures that no more heat
than that effectively necessary is produced. Use room thermostats to adjust the temperature without overheating the rooms. Every
extra degree centigrade means consuming approximately 6% more. Also adjust room temperature in relation to the use of each
room. For example, bedrooms or rooms that are not used as much can be heated to a lower temperature. Use the programmable
timer (if available) and set the night-time room temperature at approximately 5°C lower than that during the day. There is no
appreciable saving to be achieved by setting it any lower. Lower the temperature setpoint only before a long period of absence,
e.g. a holiday. Do not cover radiators in order to allow correct air circulation. Do not leave the windows partially open to ventilate
the rooms but open them completely for a short period.
Domestic hot water
Setting the domestic hot water at a comfortable temperature without mixing it with cold water saves a lot of money. Any further
heating causes a waste of energy and a greater creation of limestone (the main cause of the abnormal operation of the boiler).

13. APPENDIX

13.1 PRODUCT FICHE

BAXI EVOLUTION PRIME
Space heating - Temperature application
Water heating - Declared load profile
Seasonal space heating energy efficiency class
Water heating energy efficiency class
Rated heat output (Prated or Psup)
Space heating - Annual energy consumption
Water heating - Annual energy consumption
Seasonal space heating energy efficiency
Water heating energy efficiency
Sound power level L WA indoors
(1) Electricity
(2) Fuel
1.24
24
-
XL
-
20
kW
24
62
GJ
74
33
kWh
-
(1)
GJ
17
-
(2)
93
%
93
%
86
-
48
dB
50
15
26
28
30
Medium
XL
XL
XL
24
20
24
74
62
74
33
33
33
17
17
17
93
93
93
85
85
87
50
48
50
7730585(02-11/19)

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido