Technical Data - Hilti SIW 22T-A Manual De Instrucciones

Ocultar thumbs Ver también para SIW 22T-A:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
LEDs light constantly
LED 1, 2, 3, 4
LED 1, 2, 3
LED 1, 2
LED 1
-
en
-
NOTE
Indication of the charge status is not possible while the power tool is in operation or immediately after operation. If the
battery charge status LEDs flash, please refer to the information given in the Troubleshooting section.
3.5 Power tool overloading and overheating indicator
The power tool is equipped with an electronic protection system to prevent overloading and overheating. The power
tool switches itself off automatically in the event of overloading and overheating. After releasing the control switch, the
power tool may not restart immediately when the switch is pressed again (while the power tool is cooling down).
LEDs light constantly
-

4 Technical data

Right of technical changes reserved.
Power tool
Rated voltage (DC voltage)
Weight in accordance with EPTA
procedure 01/2003
Rated speed under no load
Impact speed
Torque
Standard screws
High-strength screws
Chuck
Speed control
Forward / reverse
Deep discharge protection
Noise information in accordance with EN 60745:
Power tool
Sound (power) level, L
Uncertainty for the sound (power) level, K
Emission sound pressure level, L
Uncertainty for the sound pressure level, K
14
LEDs blink
-
-
-
-
LED 1
LED 1
SIW 22T‑A ½"
21.6 V
3 kg
0...2,000/min
Max. 2,500/min
450 Nm
M12 ‑ M24
M8 ‑ M16
½" square drive
Electronic, by way of the control
switch
Electronic switch with interlock to
prevent switching while running
Yes
WA
WA
pA
pA
LEDs blink
LED 1, 2, 3, 4
SIW 22T‑A ½"
108 dB (A)
3 dB (A)
97 dB (A)
3 dB (A)
Charge status C
C ≧ 75 %
50 % ≦ C < 75 %
25 % ≦ C < 50 %
10 % ≦ C < 25 %
C < 10 %
The battery has overheated
Power tool status
Power tool overloaded or
overheated
SIW 22T‑A ¾"
21.6 V
3.2 kg
0...2,000/min
Max. 2,500/min
450 Nm
M12 ‑ M24
M8 ‑ M16
¾" square drive with locking pin
Electronic, by way of the control
switch
Electronic switch with interlock to
prevent switching while running
Yes
SIW 22T‑A ¾"
111 dB (A)
3 dB (A)
100 dB (A)
3 dB (A)