Setting The Water Softener; Wash And Rinse Tank Temperatures - Classeq D400 Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
Classeq Under Counter Range - User Manual
Caution
Only use granulated salt (max. grain size 5 – 7
mm). Salt tablets are not suitable.
Caution
If the Reservoir Cap is not properly secured,
water and/or chemicals can leak in or out of the
unit causing damage to the warewasher.
5.5.2

Setting the water softener

Check the hardness of your water supply (°d). You can establish
the hardness of your water supply yourself using a simple water
hardness testing kit or you may be able to get this information
from your local Water Supply Company. Once you have this data,
complete the following steps.
Refer to the Water Softener settings table to find the setting
required for your water hardness.
Enter Commissioning Mode - press and hold the Exit (1) and
Enter (2) buttons simultaneously for 3 seconds (►5.2).
Using the Up and Down keys (5 and 6), scroll to the water
hardness menu (h**) and press Enter (2).
The display will flash.
Use the Up and Down keys (5 and 6) to scroll to the setting you
require and press Enter (2).
Press Exit (1) until the warewasher exits Commissioning Mode
and returns to the off state.
5.6

Wash and Rinse Tank Temperatures

The Wash and Rinse Tank (Boiler) temperatures have been
factory set to pre-set temperatures. These temperatures do not
normally need to be adjusted by the user.
Please refer to the latest version of the Engineers Manual on the
Classeq website for full information regarding temperatures and
interlock settings.
UK
15

Publicidad

Tabla de contenido

Solución de problemas

loading