Operating Instructions
Before carrying out any work to the
operator, always pull out the mains plug!
All persons using the door system must be
shown how to operate it properly and
safely:
When the operator is being used, the
opening and closing cycles must be
monitored.
Keep hand transmitters out of the reach of
children.
It must be ensured that neither persons
nor objects are located within the door's
range of travel.
Functional sequence
The garage door operator can be actuated via
i m p u l s e g e n e r a t o r s s u c h a s h a n d
transmitters, key switches etc. It is only
necessary to give a short, sharp impulse.
Initial impulse:
The operator starts up and causes the door to
travel to the set OPEN or CLOSE end-of-
travel positions.
Impulse generated whilst the door is moving:
the door stops
A new impulse:
the door continues to move but in the opposite
direction.
Internal safety device
If the closing door encounters an obstruction,
the operator stops and causes the door to
open to its top end-of-travel position in order to
clear the obstruction.
During the last 2 seconds of the closing cycle,
the door only opens slightly, this being
sufficient to clear the obstruction but
otherwise barring anyone from taking a look
into the garage.
If the opening door encountes an obstruction,
the operator stops immediately. The door can
be closed again by generating a new impulse.
External safety devices
Connecting plan figure 13
Wicket door contact (STOP A)
An open wicket door stops the operator
immediately or stops it from starting up.
Dear customer,
During production the garage door operator
you have purchased has undergone various
checks by the manufacturer to ensure that it
is of impeccable quality. Should this operator
or parts of it prove to be of no use or limited
use as a result of proven material or
manufacturing defects, we shall rectify this,
at our discretion, through free-of-charge
repair or replacement.
We shall not accept any liability for damage
as a result of unsatisfactory fitting and
installation, improper putting into service,
incorrect operation and maintenance,
excessive use and overloading as well as
Retain these installation, operating and maintenance instructions for the full duration of the operator's service life!
Photocell (STOP B)
If the photocell is interrupted whilst the door is
closing, the door stops and reverses direction.
An interruption whilst the door is opening has
not effect.
Quick release
During adjustments, in the event of a power
failure or malfunctions the door can be
disengaged from the operator by actuating the
pull cord on the carriage and then operated
manually.
If the door is to be operated manually over a
longer period of time, then the existing locking
pin must be inserted (see figure 12). The door
latches, put out of service for power operation,
must be refitted, otherwise the door is not
latched in the closed position.
To restore power operation, return the locking
pin to the parking position (a) and put the
latches put out of service.
After an impulse has been generated, the door
automatically latches with the door operator.
Lighting
The lighting switches on automatically
whenever a start impulse is generated and
switches off again after the set time phase
(factory setting approx. 90 seconds).
A second button on the hand transmitter can
be programmed for 4-minutes light (figure 16).
When the button on the hand transmitter is
pressed, the light switches on independent of
the motor and switches off again after approx.
4 minutes.
Changing the light bulb:
Pull out the mains plug and open the lamp
cover using a Phillips screwdriver size 2 x 100.
Replace the light bulb (230 V, 40 W, base E27)
and screw the lamp cover back on.
Signal light
If a signal light for signalling the opening and
closing phases is installed, this flashes
together with the lamp in the operator as soon
as a start impulse is generated. The operator
starts with a time-delay in accordance with the
set warning phase (see menu stage 7).

Terms of the Guarantee

Any alterations or modifications carried out to
the operator and accessory parts by the
customer. The same shall also apply for
damage incurred during transit or as a result of
force majeure, external influences or natural
wear as well as special atmospherical
stresses. We cannot accept any liability
following alterations or modifications of
functional parts carried out by the customer.
We must be notified of any defects
immediately in writing; on request the parts in
question are to be made available to us.
Hand transmitter
Programming further hand transmitters:
See menu stages 1 and 2 (figure 15 and 16).
Changing the battery: Slide back the battery
compartment cover on the hand transmitter.
Take out the battery.
Insert a new battery (alkaline 23A, 12V) and
be sure polarity correctly!
Slide the cover back on.
Empty batteries must be disposed of
separately (toxic waste)!

Maintenance / Checks

For your own safety we recommend
that the door system be checked by a
specialist after initial installation and
then regularly at intervals of 1 year
minimum.
Monitoring the force limit
The operator control unit features a 2-
processor safety system to monitor the force
limit. The integral force cut-out is
automatically tested at each end-of-travel
position.
The door system must be checked before
being put into service and at least once a year
thereafter, during the course of which, a check
of the force limit facility (figure 21) must also
be carried out!
Caution! If the closing force is set too
high, persons can be placed at risk of
injury.
The opening force can be re-adjusted in menu
stage 5, the closing force in menu stage 6.
We shall not bear the costs for dismantling
and installation, freight and carriage. If a
complaint is proven to be unjustified, the
customer must bear our costs.
This guarantee is only valid in conjunction
with the signed invoice and commences on
the day of delivery. The manufacturer
guarantees that the product is free of defects.
The warranty is granted for a period of 24
months, in as far as the verification overleaf
has been properly filled out. Otherwise the
warranty shall expire 27 months after the date
of manufacture.