Tabela 3. Dimensión de la banda de bornes - 60 Hz - unidad estándar
Tam.
Potencia
Bloques
unid.
nominal
de terminaless
208/60/3
#6 - 350 MCM
230/60/3
#6 - 350 MCM
20
380/60/3
#6 - 350 MCM
460/60/3
#6 - 350 MCM
575/60/3
#6 - 350 MCM
208/60/3
#6 - 350 MCM
230/60/3
#6 - 350 MCM
26
380/60/3
#6 - 350 MCM
460/60/3
#6 - 350 MCM
575/60/3
#6 - 350 MCM
208/60/3
#6 - 350 MCM
230/60/3
#6 - 350 MCM
30
380/60/3
#6 - 350 MCM
460/60/3
#6 - 350 MCM
575/60/3
#6 - 350 MCM
208/60/3
#6 - 350 MCM
230/60/3
#6 - 350 MCM
35
380/60/3
#6 - 350 MCM
460/60/3
#6 - 350 MCM
575/60/3
#6 - 350 MCM
208/60/3
#6 - 350 MCM
230/60/3
#6 - 350 MCM
40
380/60/3
#6 - 350 MCM
460/60/3
#6 - 350 MCM
575/60/3
#6 - 350 MCM
208/60/3
#6 - 350 MCM
230/60/3
#6 - 350 MCM
52
380/60/3
#6 - 350 MCM
460/60/3
#6 - 350 MCM
575/60/3
#6 - 350 MCM
208/60/3
#6 - 350 MCM
230/60/3
#6 - 350 MCM
60
380/60/3
#6 - 350 MCM
460/60/3
#6 - 350 MCM
575/60/3
#6 - 350 MCM
1. Disyuntor y disyuntor de fallas altas opcionales
2. En esta dimensión acepta dos conductos por fase.
3. Solamente cables de cobre, de acuerdo con la ampacidad mínima del circuito (AMC) especificada en la placa de identificación de la unidad.
4. Datos del circuito uno. El segundo circuito es siempre el mismo.
5. n/d - no disponible.
CG-SVX17C-PT
Alimentación de punto único
Disyuntor
de falla
estandár¹
#3 - 3/0
#3 - 3/0
#10 - 1/0
#10 - 1/0
#10 - 1/0
#6 - 350 MCM
#6 - 350 MCM
#10 - 1/0
#10 - 1/0
#10 - 1/0
#6 - 350 MCM
#6 - 350 MCM
#3 - 3/0
#10 - 1/0
#10 - 1/0
#6 - 350 MCM
#6 - 350 MCM
#3 - 3/0
#3 - 3/0
#10 - 1/0
3/0 - 500 MCM²
3/0 - 500 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
3/0 - 500 MCM²
3/0 - 500 MCM²
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
3/0 - 500 MCM²
3/0 - 500 MCM²
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
Disyuntor
Bloques
de falla alta¹
de terminales
#3 - 3/0
#3 - 3/0
#10 - 1/0
#10 - 1/0
n/d
#6 - 350 MCM
#6 - 350 MCM
#10 - 1/0
#10 - 1/0
n/d
#6 - 350 MCM
#6 - 350 MCM
#3 - 3/0
#10 - 1/0
n/d
#6 - 350 MCM
#6 - 350 MCM
#3 - 3/0
#3 - 3/0
n/d
3/0 - 500 MCM²
#6 - 350 MCM
3/0 - 500 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
n/d
#6 - 350 MCM
3/0 - 500 MCM²
#6 - 350 MCM
3/0 - 500 MCM²
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
n/d
#6 - 350 MCM
3/0 - 500 MCM²
#6 - 350 MCM
3/0 - 500 MCM²
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
n/d
#6 - 350 MCM
Instalación - Eléctrica
Alimentación de punto doble
Disjuntor
de falla
estandár¹
n/d
n/d
n/d
n/d
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#10 - 1/0
#10 - 1/0
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#10 - 1/0
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
Disyuntor
de falla alta¹
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#10 - 1/0
n/d
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
n/d
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
#6 - 350 MCM
n/d