6.4 Technical specifications
Installation dimension
A
(retracted length)
Lift
Weight
Supply voltage:
Protection category
Lifting speed
Lifting force
Power consumption (primary) at nominal load
Duty cycle
The synchronous run accuracy at synchronous
run
Operating temperature (min./ max.)
6.4.1 Performance chart
The lowering speed is equivalent to about the idling speed.
with 200 mm lifting
range
with 300 mm lifting
range
with a lifting range
from 400 mm
Pressure
Tension
Lifting force
6. Product Information
Version A
410 mm
460 mm
Lifting range + 110 mm
200 - 600 mm
5.2 - 8.0 kg
IP54 Motor housing at the top, otherwise IP30
20 mm/s
2000 N
2000 N
7 A at U= 24VDC
S3 / 10 % for 20 minutes
(2 minutes operating time with 18 minutes operating t
0-4 mm
-20° Celsius / +60° Celsius
Version B
24 VDC
8 mm/s
4500 N
4000 N
0-2 mm
41