8.

Dimensions

9.

Assembly

Warning!
Protect the power supply with a residual current circuit breaker (RCD).
Failure to observe this instruction can result in death or material damage due to
electric shock or fire, for example.
If a faulty installation results in adjacent urinals interfering with each other, this can
be rectified by altering the sensitivity and by a selectable immunity mode
(see
Chapter
9.1
Mount the solenoid valve (d) within a radius of 0.3 m from the siphon.
Take note of the flow direction.
9.2
Connect the solenoid valve (d) with the water connection and line urinal.
9.3
Check the function of the sensor (see
9.4
Secure the sensor (a) using the pre-installed hook strip on the siphon (b).
9.5
Connect the control unit (c) to the solenoid valve (d) and the sensor (a).
9.6
Mount the line urinal.
The piping (h) between the urinal outlet (g) and the siphon (b) must be provided by
the customer.
9.7
Connect the urinal outlet with the siphon (b).
9.8
Open the water volume regulator with an Allen key.
j: Closed
k: Open
9.9
Connect the power pack (e) to the power supply (f, 230 V AC).
9.10 Pour at least 2 l of water into the line urinal.
• Following the connection of the power supply, there is a lock time of 2 minutes.
• The system is now operational.