VDS-BUS2 Programming
VDS-BUS2 Programming
To reset mapping:
- disconnect power supply.
- connect the power supply to the
amplifi er by pressing the programming
button and holding it until you hear the
confi rmation beep.
ADVANCED PROGRAMMING: Lock-Release Timing
There are two programmable lock-release activation times:
- Lock-release time set from the residence.
- Lock-release time set from the exit button (connected to the "BS" and "-" ter-
minals).
BUTTON Panel Programming
Carry out the following steps:
1.- With the power supply disconnected, short circuit the "Bs" and "-" (negative)
amplifi er terminals (or press the exit button where one exists).
2.- Maintaining the short-circuit induced above connect the system's power
supply (at this point it will no longer be necessary to maintain the short circuit or
hold down the exit button).
A confi rmation tone will sound once you enter programming mode.
3.- Following the confi rmation tone, the lock-release time as currently pro-
grammed from the residence will be indicated by way of a number of beeps
at 0.5 second intervals.
4.- Once these indicator tones have concluded, or before they conclude, press
any button on the panel, with one press for each second to be programmed
(from 1 to 99 seconds).from the residence or following the indicator tones), wait
5 seconds before taking any other action.
Amplifi er
CN1
AMPLIFICATEUR BUS-2
CN2
JP2
MASTER
SLAVE
JP3
LEDS ON
LEDS OFF
CN1
PACK EXTENSION
CN2
TARJETERO
CARD HOLDER
CN3
LEDS ESTADO
STATUS LEDS
CN4
TEST
AMPLIFICADOR BUS-2
A
BUS-2 AMPLIFIER
AUDIO
B
C
BUS-2 VERSTÄRKER
D
IDIOMA
PAN & TILT
LANGUAGE
10
EXIT
EXIT
MIC
BUS-2
-
B
B
NC NO C
BS
+12
CN3
CN4
S
PROG
SW1
SW1
Pag 13