5.3.2 Managing PS 200 S Ferroscan projects and data 5
The "Projects" submenu provides access to functions that let you manage projects, display and analyze recorded
scans and import new data from the PS 200 S Ferroscan.
1.
Transfer the scan data directly from the PS 200 S Ferroscan system to the PSA 100 monitor via the infrared
interface. Further information about importing PS 200 S Ferroscan data can be found in the PS 200 operating
instructions.
2.
Alternatively, the PUA 95 micro USB cable can be used to transfer scan data from the PSA 55 infrared adapter to
the PSA 100 monitor. Further information about the PSA 55 infrared adapter can be found in the PS 200 operating
instructions.
3.
Select the Projects function from the main menu.
4.
Select the desired project. The active project can be identified by its "dog ear" at top right.
NOTE The currently active project can also be accessed directly from the main menu by way of the Openproject
function button.
5.
Set the control behavior of the 4-way controller using the function button at top left.
6.
The Param. and Visu-alization function buttons can be used to change the visualization and calculation parameters.
7.
The Extras function button provides access to additional functions including the ability to export a simple report
in PDF format or to set a marker position.
8.
Using the PSA 92 USB data cable, the data from the PSA 100 monitor can be transferred to a PC for further
analysis.
6 Settings
6.1 The following settings can be adjusted:
Brightness
Volume level
Date / time
Power modes
Country settings
NOTE
Press the "Help" button to display the complete operating instructions.
en