The 4-way controller can be used to shift the focus, change parameter values or, depending on the setting, shift the
cross hairs or change the layer thickness/depth, etc.
The Ok confirmation button can be used to select the object in focus or to start data processing.
5.3 Project and data management
Ferroscan and X-Scan data can be managed within a project at the same time.
5.3.1 Managing PS 1000 X-Scan projects and data 4
en
The "Projects" submenu provides access to functions that let you manage projects, display and analyze recorded
scans and import new data from the PS 1000 X-Scan.
1.
Import the data (projects / scans) directly from the PS 1000 X-Scan using the PSA 50/51 data transfer cable.
2.
Select the Projects function from the main menu.
3.
Select the desired project. The active project can be identified by its "dog ear" at top right.
NOTE The currently active project can also be accessed directly from the main menu by way of the Openproject
function button.
4.
Select the desired scan.
The scan is then displayed.
5.
Set the control behavior of the 4-way controller using the function button at top left.
6.
Use the function button to set the display mode to "2D" or "3D".
7.
The Param. and Visu-alization function buttons can be used to change the visualization and calculation parameters.
If you change the parameters under Param. the data must be recalculated. To do this, press the Ok confirmation
button.
8.
The Extras function button provides access to additional functions including the ability to export a simple report
in PDF format or to set a marker position.
9.
The data can be transferred to a PC for further analysis using the PSA 92 data transfer USB cable.