Operation
➤ Push the sleeve of the hose line (3) into the safety coupling (5) until you hear it
latch.
➤ Open the valve (6) on the safety coupling (5).
➤ Open the valve of the gas cylinder or container.
!
WARNING!
Never check for leaks with an open flame or near sources of ignition.
➤ Check all connections with leak spray.
There are no leaks at the connections if no bubbles form.
Disconnecting the cooler from the external gas supply
➤ Close the valve (6) of the safety coupling (5) of the gas port.
➤ Disconnect the hose line (2) by pushing the sleeve towards the valve handle.
➤ Put the cap (4) onto the safety coupling (5).
➤ Turn the temperature controller (fig. 3 2, page 5) to "".
6.6
Connecting the ACX35 or ACX40 cooler to a gas
cylinder
Note the following country-specific gas type and gas pressure categories:
Country
Denmark, Finland, Hungary, Norway, Poland, Sweden I
Belgium, Czech Republic, France, Italy, The Nether-
lands, Portugal, Slovakia, Spain, United Kingdom
Austria, Germany, Luxembourg, Switzerland
➤ Connect the ACX35 or ACX40 cooler to the gas hose (fig. 6, page 7) and the
gas cylinder (fig. 7, page 8).
20
ACX35, ACX40, ACX40G
Device categories
B/P – 30 mbar
3
I
+ – 28 – 30 / 37 mbar
3
I
B/P – 50 mbar
3
EN