Setting up and connecting the cooling device

5.1

Operating and display elements

No. in
fig. 1,
Explanation
page 3
1
Temperature controller
2
Error code LED
3
Operating panel with ventilation slots (only MDC-90 and
MDC-110)
Error codes in the error code LED, see chapter "Troubleshooting" on
page 34.
On the MDC-90 and MDC-110 models the temperature control
and the error code LED are on the device operating panel. On the
MDC-50 and MDC-65 models, the temperature control and the
LED are integrated in the device.
6
Setting up and connecting the cooling
device
6.1
Setting up the cooling device
The device is designed for ambient temperatures between +16 °C and
+32 °C. In continuous operation, the air humidity may not exceed 90 %.
Set up the cooling device in a dry, sheltered place. Avoid placing it near heat
sources such as radiators, gas ovens or hot water pipes. Do not let it stand
in the direct, strong sunlight.
The cooling device must be positioned so that heated air can dissipate easily.
Therefore make sure there is adequate ventilation (fig. 2, page 4).
No. in
fig. 2,
Explanation
page 4
1
Hot waste air
2
Cold intake air
3
Condenser
4
With cover panel 50 mm above
26