ENGLISH
Important: Never look directly into the light source! Don't use the effect in the presence of
persons suffering from epilepsy.
DESCRIPTION:
1. Optical lens with manual focus adjustment
2. Hanging bracket with 2 knobs on both sides to fasten the unit and a mounting hole to
fix a mounting hook.
3. Mains input with IEC socket and integrated fuse holder, connect the supplied mains
cable here.
4. Lamp compartment, to be opened with this screw.
5. Rubber feet, used to put the unit on a flat surface
6. ¼" jack used to connect the optional CA-8 controller.
7. DIP switches, used to set the DMX-starting address of the unit.
8. DMX input: 3pin male XLR-connector used to connect universal DMX-cables. This
input receives instructions from a DMX-controller or from another Dualscan light effect
when used in master/slave mode.
9. DMX output: 3pin female XLR-connector used to connect the Dualscan with the next
unit in the DMX chain or with another Dualscan when used in master/slave mode.
10. Scanning mirror.
11. Earth connection
12. Strong handle for easy transport
JB SYSTEMS®
OPERATION MANUAL
3/40
DUALSCAN
ENGLISH
LAMP (RE)PLACEMENT
In case of replacement of the lamp or maintenance, do not open the
fixture within 10 minutes until the unit cools down after switching off.
Always unplug the unit before servicing! Always use the same type of
spare parts (bulbs, fuses, etc.) When replacing parts, please only
genuine spare parts.
• Switch off the unit and unplug the mains cable.
• Wait for about 10 minutes until the unit has been cooled down.
• Use a screwdriver to unscrew the screw that closes lamp compartment of the fixture.
• On the inside you will see the lamp socket. Tear the lamp socket gently out of the lamp
compartment.
• Unplug the old lamp. Hold the lamp socket while unplugging the lamp instead of pulling
the cable!
• Hold the lamp socket while pressing the new lamp gently in the socket.
Attention! Check the label on the backside of the device or see the technical
specifications in this manual to know which lamp should be used. Never install lamps
with a higher wattage! Lamps with higher wattage generate temperatures the device was
not designed for. If the device uses a lamp transformer, it will burn due to current
overload.
• Don't touch the bulb inside the reflector of the lamp with bare hands! This drastically
shortens the lifespan of the lamp. If you touched the lamp, clean it with a cloth and a little
denatured alcohol. Wipe the lamp off before installing.
• Put the new lamp back inside the unit. Be sure that the wires don't touch the lamp.
• Close the lamp compartment with the screw.
• Done!
OVERHEAD RIGGING
• Important: The installation must be carried out by qualified service personal only.
Improper installation can result in serious injuries and/or damage to property.
Overhead rigging requires extensive experience! Working load limits should be
respected, certified installation materials should be used, the installed device
should be inspected regularly for safety.
• Make sure the area below the installation place is free from unwanted persons during
rigging, de-rigging and servicing.
• Locate the fixture in a well ventilated spot, far away from any flammable materials and/or
liquids. The fixture must be fixed at least 50cm from surrounding walls.
• The device should be installed out of reach of people and outside areas where persons
may walk by or be seated.
• Before rigging make sure that the installation area can hold a minimum point load of
10times the device's weight.
• Always use a certified safety cable that can hold 12times the weight of the device when
installing the unit. This secondary safety attachment should be installed in a way that no
part of the installation can drop more than 20cm if the main attachment fails.
• The device should be well fixed; a free-swinging mounting is dangerous and may not be
considered!
• Don't cover any ventilation openings as this may result in overheating.
JB SYSTEMS®
OPERATION MANUAL
4/40
DUALSCAN