MAINTENANCE
REPLACING FUEL FILTER
See Figure 23.
Occasionally the fuel filter may become clogged and need
replacing. To purchase a replacement fuel filter contact
RIDGID customer service at 1-866-539-1710.
To replace:
Turn the fuel valve to the OFF position.
Remove the fuel lines from both sides of the filter by
squeezing the ends of the retaining clips with pliers.
Slide the fuel lines off.
Replace with new fuel filter.
Reinstall fuel lines and retaining clips to new fuel filter.
Turn the fuel valve to the ON position.
STORAGE
When preparing the generator for storage, allow the unit to cool for 30 minutes then follow the guidelines below.
STORAGE
TIME
Less than 2
Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances.
months
2 months to 1
Drain fuel from carburetor.
year
Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances.
1 year or more
Drain fuel from the carburetor.
Remove spark plug.
Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances.
Put a tablespoon of engine lubricant into the spark plug cylinder. Turn the engine slowly with the pull rope
to distribute the lubricant.
Reinstall spark plug.
Change engine lubricant.
After removal from storage:
Fill with fresh gasoline.
NOTE: If storing gasoline in suitable container for later use, make sure gasoline has been treated with fuel stabilizer
according to stabilizer manufacturer's instructions.
TRANSPORTING
Turn the engine OFF ( O ).
Turn the fuel valve to the OFF position.
Allow 30 minutes of "cool down" time before transporting
the machine. Make sure engine and exhaust of unit are
cool.
Lower the handle.
Keep unit level while transporting to prevent fuel spillage.
If transporting in a vehicle, drain the fuel tank and securely
restrain the generator.
Do not drop or strike unit or place under heavy objects.
PRIOR TO STORING