Maintenance • Mantenimiento
Entretien • Manutenção
Prefilter
Main filter
Prefiltro
Filtro principal
Préfiltre
Filtre principal
Filtro prévio
Filtro principal
[gal]
200
4.9
400
9.8
*1 EWC 150202 = European waste disposal key
22
Filter mat
Esterilla filtrant
Elément filtrant
esteira de filtro
[gal]
[inch]
5.4
7.58 x 3.15 x 1.18
10.6
7.58 x 3.15 x 1.18
Código de residuos europeo
Code européen de déchet
Europese afvalsleutel
Filter replacement
Weight
This is necessary when
Order Ref.
Peso
Referencia
- the water being discharged is too
Poids
No. de comm.
Peso
N°. de encom.
[lb]
- the filter is clogged (see 'Checking of
13.2
XV KT15 CF1
Note:
25.4
XV KT16 CF1
• Please observe the requirements of the
• Only use original filter sets in order to
• In the event of significant differences
• Remove plastic bag before filter instal-
Procedure
1. Place new filter set near the unit. Keep
2. Shut off condensate inlet
3. Open KCF lid.
45°
4. Get hold of the filter handles and slowly
5. Remove the handles and fit them onto
6. Put the drained filter set into the plastic
7. Insert the main filter into the filter
8. Insert the prefilter above the main
9. Open condensate inlet.
english
cloudy (see 'Wastewater test')
level indicator')
Water Resources Act and other legal
regulations in your country pertaining
to the use and handling of filters. As
part of the operator's duty of care you
should always keep a spare filter set.
ensure operational reliability.
compared with the specifications of
the general technical approval, e.g. the
employment of non-original filters, the
approval no longer covers the usability
of the KCF product. In such cases,
individual approval of the responsible
local authority will be required.
lation!
the PE packaging of the new set for
putting in the old filters.
Open the service valve and let the
liquid drain off to below the level of the
cartridge.
pull the old prefilter and main filter out of
the container, turn filters counterclock-
wise by 45°, place on the top edge of
the container and allow to drain.
the new main filter.
bag and ensure correct disposal *1.
receptacle of the container using the
handles, and introduce two thirds of
the container in a downward direc-
tion. When encountering noticeable
resistance, manually push into the final
position. Snap handles into place at the
side of the filter receptacle.
filter and fit onto the guide pipe when
closing the housing lid.
Close the service valve.
KCF 200, 400