1. Power tool
Symptom
Tool doesn't run
Tool suddenly stopped
Tool bits
-can't be attached
-fall off
Holes can't be smoothly
drilled.
Battery cannot be
installed
2. Charger
Symptom
The charge indicator lamp
is rapidly fl ickers purple,
and battery charging
doesn't begin.
The charge indicator lamp
blinks red, and battery
charging doesn't begin.
Battery usage time is
short even though the
battery is fully charged.

TROUBLESHOOTING GUIDE

WARNING
Possible cause
No remaining battery power
Battery isn't securely attached.
Concrete dust has accumulated on
the terminals of the battery installation
compartment as well as on the battery
sliding grooves.
The battery was attached while the switch
trigger was ON.
Tool was overburdened
Reactive force control was activated
Battery or tool overheated
The shape of the attachment portion
doesn't match
The drill is worn
Attempting to install a battery other than
that specifi ed for the tool.
Possible cause
The battery is not inserted all the way.
There is foreign matter in the battery
terminal or where the battery is attached.
The battery is not inserted all the way.
The battery is overheated.
The battery's life is depleted.
Remedy
Charge the battery.
Push in the battery until a click is heard.
Clean off the accumulated concrete dust
with a dry cloth.
Attach the battery when the switch trigger
is OFF.
Remove the cause of the overburdening.
See "Reactive force control".
Allow the tool and battery to thoroughly
cool.
For the SDS-max shank type, use a bit with
a diameter that is within the designated
range.
Replace with a new drill.
Please install a multi volt type battery.
Remedy
Insert the battery fi rmly.
Remove the foreign matter.
Insert the battery fi rmly.
If left alone, the battery will automatically
begin charging if its temperature decreases,
but this may reduce battery life. It is
recommended that the battery be cooled in
a well-ventilated location away from direct
sunlight before charging it.
Replace the battery with a new one.