VOLTWERK VS 3 Instrucciones De Servicio página 102

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 126
Voltwerk VS 3, 4, 5
CAN cable
For the connection you will require a 5-pin CAN cable with a
5-pin M12 socket on one end and a 5-pin M12 plug on the
other.
Damage due to incorrect connection.
Incorrect wire configuration may restrict functionality of the
inverter, or may damage it.
| Check the correct assignment of the wires to the female
connectors according to the wiring diagram.
(4)
(5)
(1)
5.5:
Wiring diagram: plug (left) and socket (right)
No.
Assignment
(1)
(2)
CAN GND
(3)
CAN H
(4)
CAN L
(5)
Operating manual
5 Installation
(3)
(3)
(5)
(2)
(2)
(4)
(1)
39

Publicidad

Tabla de contenido
loading

Productos relacionados para VOLTWERK VS 3

Este manual también es adecuado para:

Vs 4Vs 5

Tabla de contenido