3 Technical description
12
3.3
Display
All string inverters have a 2-line display.
Operation
A button is available for operation on the bottom of the
device. You have two possible ways of operating the button:
Quick press
Press and hold
Normal mode
In normal mode, the display automatically shows the menu
items one after another. Pressing the button interrupts the
current display at the required point. After one minute, the
display changes back to normal mode until you press the
button again.
a
)
Menu item
P (actual)
E (total)
E (day)
U (DC)
I (DC)
U (AC)
I (AC)
a)
Please note that the display is not a calibrated
measuring instrument.
If you want to switch to the SETTINGS menu, press and hold
the button for longer.
Operating manual
| Activates display lighting
| Changes to the next menu item
| Selects the selection value
| Confirms the entry displayed
| Changes to another menu or
submenu
Meaning
Current output in kW
Inverter yield since commission-
ing in kWh
Daily yield in kWh
Current DC voltage in V
Current DC current in A
Current AC voltage in V
Current AC current in A
Voltwerk VS 3, 4, 5