Should any problems or wear be encountered, please contact your authorized
specialist dealer immediately in order to have them corrected.

10.1. MAINTENANCE

Check
Function test of the wheel locks
Sagging of the seat and back upholstery
Check stability of footplate
Visual inspection of wear parts (E.g., tyres,
bearings)
Dirt on bearings
Push rings for damages
Folding mechanism for wear and tear
Spoke tension of the rear wheels
Screw connections
This is particularly important if you notice that the driving characteristics change,
or the wheelchair becomes less stable. We also recommend that you have the
wheelchair maintained regularly at 12 mounth intervals by your authorized specia-
list dealer. The functions described in the following list must be verified by the
user at the specified intervals. To ensure smooth operation always, the following
precautions and cleanings should be carried out. Users may carry these out
themselves:
Hair and dirt particles generally accumulate between the caster wheel
and fork. This can restrict the caster wheels from rotating smoothly. Remove the
casters and thoroughly clean the forks and casters using a mild household clea-
ner.
If your wheelchair gets wet, towel dry it as soon as possible.
Do not use the wheelchair in salt water and keep sand or other particles
from damaging the wheel bearings.
Screw connections should be checked frequently, when beginning to use
the wheelchair and after any adjustment. If a screw connection comes loose
repeatedly, please consult your specialist dealer.
10
EN
ES
Before each use
S220 Sevilla | S230 Sevilla
Monthly
X
X
X
X
X
X
X
Quarterly
X
X