3.2 Unlocking access to programming
1. Scroll through the parameters with the buttons
and
until the display shows P008;
2. Access the parameter by pressing the button
3. The
display
shows
to indicate that the control board is
waiting for the transmission of the unlocking code;
4. Within 10 sec. press the CH1 of the "TX Master",
the display shows
to the list of parameters;
5. Access to programming is unlocked.
3.3 Unlocking access to programming and global reset
WARNING!
This procedure involves the loss of all stored
settings.
The procedure allows the unlocking of the control panel without
having to know its unlocking code.
Following this release, you must program the control panel again
and adjust all operating parameters, in particular, remember
to properly set the configuration of parameters (P028 -
P029 - P030 – operator configuration). You will also need to
repeat the measurement of impact forces to ensure the installa-
tion compliance to standards.
1. Scroll through the parameters with the buttons
the display shows P008;
2. Access the parameter by pressing the button
3. The display shows alternately the writing
4. Press the button
, the display shows the flashing writing
5. Press the button again and hold for 5 seconds (releasing it be-
fore, the procedure is terminated): The display shows the fixed
writing
followed by
parameters;
6. Access to programming is unlocked.
4
Inputs configuration
Where the installation requires different commands and / or additional to
the standard ones described by plan, you can configure each input for the
operation desired (eg START, PHOTOS, STOP , etc ...).
1. Scroll down the parameters with the
ing to the desired one:
● P017=for INPUT 1;
● P018=for INPUT 2;
● P019=for INPUT 3;
● P020=for INPUT 4;
● P021=for INPUT 5;
● P022=for INPUT 6;
2. Confirm by pressing on the
P018);
3. Scroll down with the
the desired operation (refer to table "Input Configuration parameters"
on page 65);
4. Confirm by pressing on the
5. Execute the new connection to the input just reconfigured.
5
Programming complete
WARNING At the end of the programming procedure, use the buttons
operator is now ready again for new manoeuvres.
64
;
alternately
the
writing
before returning
and
;
, before returning to the list of
and
to see that correspond-
key to get access to the parameter (eg.
and
, keys to set the value corresponding to
key (display shows again P018).
until
;
;
and
until the appearance of the symbol "----", the