8.6 Overload protection

If an overload of the motor occurs during
operation, the built-in automatic reverse
changes the rotational direction of the
blade roller in an attempt to remove the
blockage automatically. If the blockage
cannot be removed after 3 changing
rotational direction, the built-in overload
protection automatically switches off the
motor.
The garden shredder can be started up
again after a cooling period of
approx. 10 minutes.
Frequent triggering of the overload
protection may be attributable to the
following causes:
– Unsuitable electric cable (
10.1)
– Power overload
– Machine overload due to excessive
quantities of shredding material

8.7 When the blade roller blocks

An overloaded motor, too much shredding
material, foreign objects or branches that
are too thick will cause the rotational
direction of the blade roller to change
automatically after a short period of time,
resulting in the blade roller coming to a
stop.
The blade roller changes rotational
direction automatically when
overloaded.
● If the blade roller stops, operate the Off
switch immediately.
● Allow the machine to cool and switch on
again as described. (
10.9)
16

9. Safety devices

9.1 Motor restart inhibitor

The machine can only be started via the
switch and not by plugging the electric
cable into the mains socket.

9.2 Shredder box

The garden shredder can only be switched
on with the shredder box installed and
locked in place.
Once inserted, the shredder box prevents
access to the rotating blade roller during
operation.

10. Operating the machine

10.1 Electrical connection of garden

shredders

Risk of injury!
Observe the instructions in section
"Warning – dangers caused by
electrical current" (
4.2).
Power supply and operating voltage must
correspond (see rating plate).
The power cable must be adequately
protected by fuse. (
16.)
Only electric cables which are no lighter
than rubber sheathed cables
H07 RN-F DIN/VDE 0282 may be used.
The plug connections must be splash
proof. Unsuitable extension cables lead to
a loss of power and may result in damage
to the motor.
The minimum cross-section of the power
cable must be 3 x 1.5 mm² for a length of
up to 25 m or 3 x 2.5 mm² for a length of
up to 50 m.
The connectors of the electric cable must
be made of rubber or have a rubber
coating and conform to the DIN/VDE 0620
standard.
This machine is intended for operation with
a power supply having a system
impedance of Z
at the transfer point
max
(house connection) of maximum
0.49 Ohm (at 50 Hz).
The user must ensure that the machine is
only operated with a power supply which
meets this requirement. If necessary, this
information can be obtained from the local
electric power company.
Your electrician can provide further
information on mains connection.

10.2 Connecting the power cable

6
● Connect the mains cable
connector to mains plug (1).
● Attach the mains cable to the strain
relief. (
10.4)

10.3 Disconnecting the power cable

● Detach the strain relief. (
10.4)
In order to prevent damage to the power
cable, it must only be disconnected by
pulling at the connector. Never pull at the
cable.
0478 201 9812 A - EN