_ECL-75_102.book Seite 43 Montag, 7. April 2008 11:31 11
ECL-75, ECL-102
➤
Connect the wire sleeves of the universal connection cable to contacts I5 and I2
on the charging current distributor.
➤
Join the on/off cable of the B2200 (item no. 4441300129) to the plug connector on
the circuit board (see fig. 10, page 11).
Note
Guide the on/off cable carefully past the fan.
➤
Connect both the wires on the universal connection cable (4441300124) to the two
wires on the on/off cable of the B2200.
7.5
DC-Kit-3 with Dometic B1600 / HB2500
Circuit diagram, see page 9
Roof air conditioner: Dometic B1600 / HB2500
Charging current distributor: ECL-102
Inverter: SinePower SP1500 (item no. MSK1500-012)
➤
Install inverter remote control MCR-8 (or MCR-9, membrane button) in an
easily-accessible place (jumper closed, refer to remote control installation manual)
and connect its cable to the inverter.
➤
Unravel the 2-wire universal connection cable (on/off cable, item no. 4441300124)
so that you have two individual wires.
➤
Use the blue wire of the universal connection cable (item no. 4441300124) to
join the I5 connection of the ECL-102 to the MCR-8 (MCR-9) remote control
(use wire sleeves).
➤
Use the brown wire of the universal connection cable to join the D+ input to the
l2 connection on the ECL-102 (use wire sleeves).
8
Adjustment
Caution
The following work must be carried out with caution and only by persons with
the necessary skills and knowledge. This is because incorrect adjustment of
the cut-in and cut-off voltages can cause the air conditioner to malfunction
and/or cause the vehicle's electrical system to fail.
Note
The voltage scale shown on the charging current distributor is a guide. If
different values are set, these must be checked using a suitable voltage
measurement device. An externally adjustable laboratory power supply can be
connected to terminals GND and D+ for this purpose.
➤
Insert the screwdriver into the axis of the potentiometer (see fig. 8, page 10). Turning
the axis clockwise increases the voltage threshold value, turning it anti-clockwise
reduces the voltage threshold value.
Note
Due to information presently available, we do not recommend a cut-off voltage
less than 11.5 V.
Adjustment
43