Dc-Kit-3 With Dometic B1600 / Hb2500; Adjustment - Waeco ECL-75 Instrucciones De Montaje

Ocultar thumbs Ver también para ECL-75:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
_ECL-75_102.book Seite 43 Montag, 7. April 2008 11:31 11
ECL-75, ECL-102
Connect the wire sleeves of the universal connection cable to contacts I5 and I2
on the charging current distributor.
Join the on/off cable of the B2200 (item no. 4441300129) to the plug connector on
the circuit board (see fig. 10, page 11).
Note
Guide the on/off cable carefully past the fan.
Connect both the wires on the universal connection cable (4441300124) to the two
wires on the on/off cable of the B2200.
7.5

DC-Kit-3 with Dometic B1600 / HB2500

Circuit diagram, see page 9
Roof air conditioner: Dometic B1600 / HB2500
Charging current distributor: ECL-102
Inverter: SinePower SP1500 (item no. MSK1500-012)
Install inverter remote control MCR-8 (or MCR-9, membrane button) in an
easily-accessible place (jumper closed, refer to remote control installation manual)
and connect its cable to the inverter.
Unravel the 2-wire universal connection cable (on/off cable, item no. 4441300124)
so that you have two individual wires.
Use the blue wire of the universal connection cable (item no. 4441300124) to
join the I5 connection of the ECL-102 to the MCR-8 (MCR-9) remote control
(use wire sleeves).
Use the brown wire of the universal connection cable to join the D+ input to the
l2 connection on the ECL-102 (use wire sleeves).
8

Adjustment

Caution
The following work must be carried out with caution and only by persons with
the necessary skills and knowledge. This is because incorrect adjustment of
the cut-in and cut-off voltages can cause the air conditioner to malfunction
and/or cause the vehicle's electrical system to fail.
Note
The voltage scale shown on the charging current distributor is a guide. If
different values are set, these must be checked using a suitable voltage
measurement device. An externally adjustable laboratory power supply can be
connected to terminals GND and D+ for this purpose.
Insert the screwdriver into the axis of the potentiometer (see fig. 8, page 10). Turning
the axis clockwise increases the voltage threshold value, turning it anti-clockwise
reduces the voltage threshold value.
Note
Due to information presently available, we do not recommend a cut-off voltage
less than 11.5 V.
Adjustment
43

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ecl-102

Tabla de contenido