REMOTE CONTROL PROGRAMMING (separating 2 bases)
Separate Two Bases - for independent adjustable base
movement, perform the following numbered procedure.
STEP 1
Unplug both bases from electrical power outlet. Position
both bases on their sides, in close proximity to each other.
CAUTION: AT LEAST TWO PEOPLE ARE RECOMMENDED FOR
HANDLING AND MOVING ADJUSTABLE BASE.
STEP 2
Locate control box on both bases. Locate dual sync cable
(FIGURE 12).
STEP 3
On each base, remove the male plug of the dual sync
cable from the control box (FIGURE 16).
STEP 4
On each base, remove the cable from the female plug
of the dual sync cable and plug it into the control box
(FIGURES 16 and 17).
FIGURE 16
MALE
PLUG
CONTROL
BOX
FEMALE
PLUG
FIGURE 17
CABLE
REMOVED
FROM
FEMALE
PLUG
STEP 5
Plug base 1 into electrical power outlet. Using a pointed
object, push the learn button in two times in rapid succession
(FIGURE 18). The underbed lighting will come on.
STEP 6
Remove the battery compartment door from the both
remote controls.
CABLE
REMOVED
FROM
CONTROL
STEP 7
BOX
On remote control 1, press and hold the learn switch
(FIGURE 19) until the underbed lighting goes off.
FIGURE 19
CONTROL
BOX
STEP 8
Repeat Steps 5, 6 & 7 with base 2 and remote control 2.
STEP 9
Turn both bases over so they are resting on their legs.
CAUTION: AT LEAST TWO PEOPLE ARE RECOMMENDED FOR
HANDLING AND MOVING ADJUSTABLE BASE.
Independent remote control operation is now
restored (remote control 1 operating base 1; remote
control 2 operating base 2).
Prodigy™ 2.0 Adjustable Base Owners Manual 99301584-c
REMOTE 1
REMOTE 1
FIGURE 18
LEARN
BUTTON
BATTERY
COMPARTMENT
DOOR
BASE 1
BASE 2
CONTROL
BOX
LEARN
SWITCH