- press the Kis knob or the ENTER button to
confirm the securing of the template;
- slowly turn the template towards the operator
to automatically enable the clamping brake
(fig.30);
- slowly lower the wheel guard (fig. 31), the ma-
chine will automatically calibrate the sensor.
82
29
If the calibration has been performed successfully,
a consent message is displayed.
On the contrary, the display of the message A20
indicates that:
- the position of the calibration template during
the calibration phase is not correct. Therefore,
position the template correctly, checking that
the hole in the ultrasonic sensor support is
aligned with the calibration template (see figure
31) and repeat the procedure.
- the internal sensor was not in the rest position.
Position it to the rest position and repeat the
procedure.
Select the Exit
gramme without performing a calibration.
30
This program displays some data that are used to
test machine operation and to detect the malfun-
ctioning of some devices. Since these data are not
useful for the operator, it is recommended that
only technical support technicians consult them.
Select the service programmes icon to display
this programme
The machine can recognise a certain number
of malfunction conditions and signals them by
displaying the relevant messages.
icon to exit the pro-
Service
.
ERROR MESSAGES
EM 9580 - Operator's manual
31