Mid - Conformity Declaration; Safety Instructions; Electro-Magnetic Interference; Care Instructions - Zenner zelsius Manual De Montaje E Instrucciones

Contador electrónico compacto de calefacción con unidad volumétrica de ultrasonidos iuf
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Deutsch
English

MID - Conformity declaration

zelsius
C5-IUF is produced and
®
tested in compliance with the Euro-
pean Measuring Instruments Direc-
tive 2014/32/EU (MID). According to
this directive, devices are no longer
carrying an initial verification stamp,
but rather the year of the device's
declaration of conformity (recogniz-
able on the front of the device, for
example: M16). The MID controls
the use of heat meters up to the
moment they are placed on the mar-
ket resp. their first putting into use.
After this, the national regulations
for devices subject to compulsory
verification apply within the EU. The
duration of initial verification validity
in Germany remains 5 years for heat
meters. After this period has expired
the measuring device may no longer
be used for billing in commercial
use. The regulations resp. validity
period may vary in other countries
of the EU.
If you have questions, please direct
them to
support@zenner.com
The declaration of conformity is
attached to each measuring instru-
ment. The latest information about
this product can be accessed or
downloaded from
22
Français
www.zenner.com

Safety instructions

Electro-magnetic interference

zelsius
C5-IUF fulfils the national
®
and international requirements for
interference resistance. To avoid
malfunctions due to other interferen-
ces, do not install fluorescent lamps,
switch cabinets or electric devices
such as motors or pumps in the im-
mediate vicinity of the meter. Cables
leaving the meter should not be laid
parallel to live cables (230V) (mini-
mum distance 0.2m).

Care instructions

Clean plastic surfaces with a damp
cloth only. Do not use any scouring
or aggressive cleaning agents! The
device is maintenance-free during
the service life. Repairs can only be
made by the manufacturer.

Installation instructions

Safety instructions for instal-
lation
Read these instructions carefully
right up to the end before starting
to mount the deice! The installation
has to be done by qualified profes-
sional personnel. The current laws
and regulations have to be obser-
ved, especially the PTB technical
guidelines K8 und K9, EN1434 part
1+6, (in Germany also AGFW direc-
tive FW202, FW510, FW218 and
DIN4713 part 4 and the initial veri-
fication directive). At devices with
M-Bus the general rules of techno-
logy and the respective regulations

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

C5-iuf

Tabla de contenido