Special safety instructions.
Wear personal protective equipment. Depending on appli-
cation, use face shield, safety goggles or safety glasses.
Where appropriate, wear dust mask, hearing protectors,
gloves and workshop apron capable of stopping small
abrasive or workpiece fragments. The eye protection
must be capable of stopping flying debris generated by
various operations. The dust mask or respirator must be
capable of filtrating particles generated by your opera-
tion. Prolonged exposure to high intensity noise may
cause hearing loss.
Before switching on, make sure that all clamping levers
and tensioning devices are well tightened. If the machine
suddenly sinks or the workpiece comes loose during the
working procedure, this can lead to serious accidents.
At a glance.
1 Grinding belt tensioning device (GX75)
2 Cover/stop (GX75)
3 Spark guard (GX75)
4 Star-knob bolt, chip/grinding-dust box (GX75)
5 Grinding rest (GX75)
6 Dust collector (GX75)
7 Lever for tilting device (GX75)
8 Side cover (GX75)
9 Mounting bolts, nuts for alignment of radius grinding
module/belt grinder
10 Spark guard
11 Wing bolts of the spark guard
12 Feed lever
13 Mounting lever
14 "Centerhöhe" adjustment (pipe center)
15 Clamping lever, adjustment "Centerhöhe"
16 "Schleiftiefe" adjustment/depth stop
17 Crank for grinding-table adjustment
18 Collection box
19 Protective devices/side covers
20 Securing screws for contact roller
21 Contact roller
22 Handwheel
23 Rapid-clamping lever for clamping of workpiece
24 Clamping lever for angle adjustment
25 Angle scale
26 Clamping jaws, fixed
27 Bracket/magazine for contact rollers
28 Casters
Assembly instructions (figures 1–3).
Belt grinder GX75.
Before any work on the machine itself, pull the
mains plug.
Dismount the spark guard (3).
Dismount the grinding rest (5), the chip/grinding-dust
box (6) and the star-knob bolt (4).
Open side cover (8).
Loosen the tensioning device (1) and remove the grinding
belt.
Shut the side cover.
Loosen the lever of tilting device (7) and set the belt
grinder to a horizontal position.
Radius grinding module GXR.
Remove the unit from its packaging and fit the accessories
as described in the data sheet.
Position the radius grinding module against the belt
grinder and align the drill holes of the screws.
Connect both units (13) with the two mounting levers.
Tighten the levers of the tilting device (7).
Fill the collection box (18) half full with water. Position
the collection box between the support columns of the
radius grinding module.
There is a fire hazard when operating the machine
without the collection box filled with water!
Mounting the contact roller.
Before any work on the machine itself, pull the
mains plug.
Loosen both wing bolts (11) and completely slide the
spark guard (10) up.
Insert a contact roller (21) with the desired diameter into
the guide fork and secure it with both screws (20).
Adjust the belt tracking each time after changing a contact
roller.
Contact rollers not in use should always be protected
against damage by placing them in the bracket/magazine
for contact rollers (27).
Mounting/replacing the grinding belt
Before any work on the machine itself, pull the
mains plug.
Open side cover (8+19).
Loosen the tensioning device (1) and mount a
75 x 2250 mm long grinding belt.
The running-direction marking of the grinding belt
must correspond with the rotation direction.
Tension the grinding belt with the tensioning device (1).
Move the grinding belt manually and observe, if it moves
off towards the left or right of the contact roller.
Adjust the guidance of the drive wheel on the belt grinder
such that the grinding belt runs centrally. The exact cali-
bration is carried out while the machine is running.
Shut the side cover (8+19).
Operating instructions.
Close the side covers (19)/(8). When the protective
devices are not mounted, clothing can get caught
by the grinding belt and lead to personal injury.
GX75/GX752H*
Switching on:
Disengage and fold up the safety pushbutton (15*). Press
pushbutton "I" (17*).
Switching off:
Fold up safety pushbutton (15*). Press pushbutton "0"
(17*).
After switching off, the machine runs on for
approx. 50 seconds.
(* see operating instructions of the machine)
Safety pushbutton:
In situations of danger, press the safety pushbutton to
switch the machine off.

Publicidad