Modbus Protocol
Communication Control
Baud rate
Data Frame
Parity
Slave No.
1. SYSTEM CONDITION CHECK
Code
Address
System Status Check
04h
30000
04h
30003
04h
30006
04h
30009
2. SYSTEM SETTING & VOLUME CHECK
Code
Address
System Status Check
04h
30001
04h
30004
04h
30007
04h
30010
3. VU METER & FAULT STATUS CHECK
Code
Address
System Status Check
04h
30002
04h
30005
04h
30008
04h
30011
26
RS-485 MODBUS PROTOCOL
9600, 19200 bps
1 Start bit, 8 Data bit, 1 Stop bit
Non Parity
1 ~ 99 (Device Setting), 1~4 (AMP No.)
Parameter
AMP no. 1
Data HI
bit 15 ~ bit 8
Reserved
Data LOW
bit 7 ~ bit 5
Reserved
bit 4
BATTERY MODE
bit 3
SLEEP MODE
bit 2
MUTE
bit 1
OUTPUT LIMIT
bit 0
POWER (0=OFF, 1=ON)
AMP no. 2
AMP no. 3
AMP no. 4
Parameter
AMP no.1
Data HI
0 ~ 99
VOLUME SET
Data LOW
bit 7 ~ bit 5
Reserved
bit 4
GAIN UP
(0=RMS, 1=PEAK)
bit 3
SLEEP MODE
(0=OFF, 1=ON)
bit 2
AMP CHECK
(0=OFF, 1=ON)
bit 1
HPF
(0=OFF, 1=ON)
bit 0
BATTERY
(0=NON, 1=YES)
AMP no. 2
AMP no. 3
AMP no. 4
Parameter
AMP no. 1
Data HI
0 ~ 99
VU METER
(0~99= Normal, 100= Cliping)
Data LOW
bit 7
AMP CHECK ERROR
bit 6
OVER SHORT, MUTE
bit 5
OVER LOAD, LIMIT
bit 4
OVER TEMP, MUTE
bit 3
OVER TEMP, LIMIT
bit 2
BATTERY LOW VOLT.
bit 1
AC LOW VOLT.
bit 0
OVER CURRENT
(0=Normal, 1=Fault)
AMP no. 2
AMP no. 3
AMP no. 4
Bytes
R/W Unit
Data Mag.
2
R
Bytes
R/W
Unit
Data Mag.
2
R
Bytes
R/W
Unit
Data Mag.
2
R
Data Type
unsigned 16
Data Type
unsigned 16
Data Type
unsigned 16