‐ EN ‐
REMEDY OF FAULTS
Malfunction
Cause
The unit is not op‐
No mains voltage
erating
The unit does not
Aerator soiled
deliver any air or
Filter felt in the pump or aerator worn
the amount deliv‐
Air hose kinked or porous
ered is insufficient.
Membrane is defective
The unit is unusu‐
Membrane is defective
ally loud
MAINTENANCE AND CLEANING
C
Replacing the filter felt in the unit
How to proceed:
1. Turn the unit over and replace both felt discs
in the housing base.
2. Reassemble the unit in the reverse order.
14
Remedy
Check the mains voltage.
Clean or replace the aerator.
Replace the filter felt.
Lay the air hose without kinks or
replace.
Replace the membrane
Replace the membrane
Replacing the filter felt in the aerator
How to proceed:
1. Take the aerator out of the water.
2. Open the aerator using a coin and replace the
felt disc.
3. Close the aerator again.
Replacing the membrane
Fitting instructions are supplied with the spare
part.
DISPOSAL
Do not dispose of this unit with domestic waste!
For disposal purposes, please use the return sys‐
tem provided. Render the unit unusable before‐
hand by cutting the cables.
OxyMax 100/200/400