Fitting the automatic charger and putting it into service
5.1
Device components
Item in
fig. 1, page 3
1
2
3
4
5
6
Fitting the automatic charger and
putting it into service
!
WARNING!
Disconnect the mains plug before connecting or disconnecting
the DC voltage connection.
Batteries with a cell short circuit may not be charged. There is
a danger of explosions due to the explosive gases.
Nickel-cadmium batteries and non-rechargeable batteries
may not be charged with the IU0U automatic charger. The
sleeves of these batteries can burst in an explosive manner.
A
NOTICE!
The IU0U automatic charger must be installed in a place that is
protected from moisture and humidity.
Make sure:
The installation location is well ventilated.
The installation surface is flat and sufficiently firm.
The air intake on the underside and the air outlet on the back of
the IU0U automatic charger must be kept clear.
To connect the IU0U automatic charger only use cables not
longer than 2 m with a cross section of 1.5 mm² or more.
➤ Fix the IU0U automatic charger with suitable screws at the desired place.
Use the Sie IU0U automatic charger's fixing holes.
➤ Fit wire sleeves to the ends of cables which you wish to connect to the
IU0U automatic charger (fig. 2 1, page 3).
26
Meaning
Fuse insert with glass fuse 10 A/250 V
"Power" indicator lamp
"Charging" indicator lamp
Connection terminal
Mains power cable (230 V)
PerfectCharge IU812
EN