EN
Operating instructions pressure measuring devices SATA adam 2, SATA adam 2 U
6.3. Personal Protection Equipment
Warning!
• Always wear approved breathing and eye protection as well as
suitable protective gloves, overall and shoes when using the device
as well as during cleaning and maintenance!
6.4. Use In Explosive Areas
The device is approved for the use / storage in explosive areas classified
as Ex-Zone 1 and 2.
The following applications and operations lead to the loss of
the explosion protection and are, therefore, prohibited:
• The SATA adam 2 must not be brought along with or used on a spray
gun in explosive areas classified as Ex-Zone 0!
• Do not use solvents and cleaning agents based on halogenised
hydrocarbons! Chemical reaction which may occur when using these
substances may be explosive!
The electronic pressure measuring device has been submitted to a design
examination and is developed, constructed and manufactured in accord-
ance with the EU directive 94/9 EU. It was classified to II 2 G Ex ia IIC T4
FM Global IS CL I, ZN 1, AEx ia IIC T4 IS CL I, DIV 1, GP A, B, C&D, T4
and may be used and stored in the explosive zones 1 and 2 up to 60°C
ambient temperature. Inspection authority: KEMA 05 ATEX 1090 X.
Ex-sign
Equipment category
IECEx label: IECEx KEM 09.0075
78
Warning! Risk of explosion!
II 2 G Ex ia IIC T4
II
2
Device category
Gas category
G
Ex
Type of ignition protection
ia
IIC
T4
Equipment category
Temperature
classification