T1 Regulación de la fuerza "EMBRAGUE"
Por medio de este trimer se puede incrementar la fuerza de impulso de los motores,
(que ha sido calibrada durante la fase de programación). Pueden existir
variaciones entre el verano y el invierno. Atención: la fuerza debe estar
adecuadamente proporcionada y debe respetar las normas vigentes.
Carga baterias
Con este conector se carga una bateria a 24 V o dos baterias a 12 V collegadas
en serie. NB: Sacar el puente y inserir el conector.
Salida 2° canal. Solo en las versiones CT-2-24S
con receptores RXI-42 o RXI-42R
Si no instala la antena exterior, para tener una recepción suficiente se
aconseja introducir un cable unipolar de 17 cm en la entrada de la antena.
T1 Regulacion del Tiempo
de "EMBRAGUE"
T2 Regulación del Tiempo
de pausa.
7

STANDARD OPERATIONS

OPEN
With the OPEN control the blinker comes on and then the
gate starts to open.
CLOSE
With the CLOSE control the blinker comes on and then the
gate starts to close.
The STOP control stops the gate and remains in that position until a
STOP
new command is given.
The STEP BY STEP control operates on the gate through remote
STEP
control or button, keeping these phases:
BY
-with an open gate starts closing in advance
STEP
-with a moving gate pulse places the system in the stop phase
-with a close gate one pulse starts opening
PEDESTRIAN
The pedestrian control permits to open only one wing (M1) in a gate with 2 wings.
For distance pedestrian control , you need to install a 2-channels receiver and
connect i to input 6+7 pedestrian and to output 3 connect the second channel
output.
This indicator light informs the user about the current state of the gate.
Closed gate: indicator light
GATE OPEN
Gate opening:
slow blinking
INDICATOR
Open gate: indicator light
LIGHT
Gate closing:
fast blinking
signalling led, coming to its original function at the end of the same.
The photocell control allows that if the beam is cut off, all commands are inhibited.
If the photocell beam is cut off while the gate is opening, itcontinues
to move until its normal pause position.
If the photocell beam is cut off during the pause, the gate remains in this
PHOTOCELL
state as long as the beam is freed. Once the beam is freed, the short
pause continues (equivalent to ¼ of the set time) and then it closes.
If the photocell beam is cut off while the gate is closing,the gate starts
opening again.
Control foto 2 intervens during the opening operations and stops the gear;
during reinstatementOpening operation will continue. During closing
FOTO 2
operation, after stop, it will continue opening.
Pause time adjustment from 2 to 180 seconds.
PAUSE
MARK WELL
: if during the opening the photocell beam is cut
TIME
off, the pause time reduced equivalent to ¼ of the set time.
The courtesy light utilizes the same blinker relay and it extends its
BLINKER OR
operation if selected for a fixed time of 3 min.
COURTESY LIGHT
off
.
indicator light.
on
.
indicator light. During planning it is used for