OPTIONS TO STANDARD OPERATION
FLASHING/COURTESY LIGHT FUNCTION
DIP SWITCH
1
With this selection, it is possible to choose between using an output as
flashing or courtesy light
PAUSE DURING OPENING OF THE PHOTOCELL
With this selection it is possible to change the photocell standard
operation. By cutting off the beam during opening, the gate stops; if the
DIP SWITCH
2
photocell beam is freed, the gate starts opening again. By cutting off
the beam during closing, the gate stops; if the photocell beam is freed,
the gate reverses the operation and starts opening again.
AUTOMATIC CLOSING BY-PASS
With this selection it is possible to reach the automatic closing by-pass.
DIP SWITCH
When the gate is completely open, it doesn't go into the rest phase for
3
the time fixed in advance but it stops until another closing command is given.
NORMAL/COMMON FUNCTION
With this selection, it is possible to change the standard operation of
DIP SWITCH
step-by-step After each command given via radio and through button
4
gate will open. This link must be link together DIP 7.
WATER HAMMER FUNCTION
DIP SWITCH
With this selection, during initial opening, you can decide to
5
let the motors make a small water hammer, in order to allow
easier electric lock unhook.
FLASHING LIGHT WARNING FUNCTION
DIP SWITCH
With this selection you have the chance to let the flashing
6
light start 3 sec. before each opening or closing.
STEP-BY-STEP WITH PAUSE FUNCTION
DIP SWITCH
With this function you can change the standard step-by-step
7
function (open Stop close) into open pause close pause
WORKING TIME AUTOMATIC PROGRAMMING
DIP SWITCH
8
ADVANCED WORKING TIME PROGRAMMING
DIP SWITCH
9
TRANSMITTER PROGRAMMING
DIP SWITCH
10
See pag. 12
11
11

CONEXIONES EXTERIORES DE SEGURIDAD

¡Atención!
Las entradas de seguridad (célula fotoeléctrica y stop), si no se utilizan,
se deben puentear.
Stop (12) con Común (16)
Ft1 (11) y Ft2 (13) con Entrada Test (31)
FT 2
La célula fotoeléctrica interviene
también en la fase de apertura.
La célula fotoeléctrica no interviene en
la fase de apertura si el dip-switch 2
FT 1
no está ubicado en on.
6
6
7
7
E