EINHELL MK 2100 E Manual De Instrucciones página 22

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
5. Operation
5.1 Description of the control elements (Fig.
7)
1.
"MODE" switch – function
2.
Unassigned
3.
"TIMER" LED – timer on
4.
"TIMER" switch
5.
"UP" selector switch – higher
6.
"ON/OFF" switch – On/Off
7.
"DOWN" selector switch – lower
8.
„Sleep" switch - sleep function
9.
„Sleep function set" LED
10. "SPEED" switch – fan speed
11. „Fan fast" LED
12. Remote control sensor
13. „Fan slow" LED
14. "COMP" LED – compressor running
15. LED – indicator panel
16. "F.W." LED – condensate tray full
17. „Fan function set" LED
18. „Automatic mode set" LED
19. „Cool mode set" LED
5.2 Switching the device on and off
Press the On/Off switch. The device starts up
automatically. If the ambient temperature:
is higher than 23°C the device will run in coo-
ling mode;
if it is between 20°C and 23°C the device will
run in fan mode.
The status of the device, or mode in which it is
running, will be shown by the corresponding
LEDs (see indicator panel).
Note: The LED indicator panel shows the current
room temperature (0-50°C).
To switch the device off, press the On/Off switch
again.
Important.
After you have switched off the unit, you must
wait at least three minutes before you switch
it on again. This protects the compressor from
overloads and considerably extends its service
life.
The cooling system switches itself off whenever
the room temperature is below the value set on
the thermostat. The air circulation/ventilation fan
continues to run as set. If the room temperature
increases again, the cooling system switches on
again.
Anleitung_MK_2100_E_SPK7.indb 22
Anleitung_MK_2100_E_SPK7.indb 22
GB
5.3 Selecting the mode
Press the "Mode" selector (MODE) in the
sequence "Automatic", "Cool", "Fan". The LED for
the selected mode lights up (see indicator panel).
5.4 Setting the set-point temperature
Press the "Warmer" selector (UP) or "Cooler"
(DOWN) to set your desired set-point
temperature. If you press the "Warmer" or
"Cooler" selector, the LED indicator panel
will show your desired set-point temperature.
Otherwise the LED indicator panel always shows
the current room temperature.
5.5 Selecting the fan speed
Press the "Fan speed" selector to set the desired
fan speed.
The LED for the mode lights up (see indicator
panel).
If the device is in "Automatic mode" (AUTO) the
fan speed will be selected automatically by the
device in dependency on the room temperature.
The corresponding LED lights up. The "Fan
speed" is deactivated.
5.6 Setting the timer
Press the switch for the "Timer" (TIMER) to
set the desired operating time (1 - 12 h). The
"Timer" (TIMER) LED lights up. If the timer is
set, the device starts automatically. If you press
the "Timer" switch, the time you have set will be
shown in the LED indicator panel. If the timer
has not been switched on, the device will run
continuously.
If the unit is connected to the voltage supply and
you press the TIMER switch, you can set the time
at which you wish the unit to be switched on. If,
for example, the timer shows "2", this means that
the device will start up automatically in 2 hours
time.
5.7 Activating the sleep function (only
possible in cooling mode)
Press the "Sleep" key to activate the sleep
function. In order to prevent undercooling, the
set room temperature increases 1 °C during the
first hour and 2 °C within 2 hours. When the sleep
function is switched off the room temperature
decreases back to the set value. After the sleep
function has been on for 12 hours the equipment
switches off automatically.
- 22 -
06.09.2016 06:54:46
06.09.2016 06:54:46

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Mk 2300 eMk 2600 e23.603.5123.603.6123.603.71

Tabla de contenido